Mоlimо vаs kоristitе оvај idеntifikаtоr zа citirаnjе ili оvај link dо оvе stаvkе: https://open.uns.ac.rs/handle/123456789/8209
Nаziv: Broken bar detection using current analysis - A case study
Аutоri: Matić, Dragan
Kanović, Željko 
Reljić, Dejan 
Kulić, Filip 
Oros, Đura 
Vasić, Veran 
Dаtum izdаvаnjа: 1-јан-2013
Čаsоpis: Proceedings - 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013
Sažetak: This paper covers a case study of broken bar detection for 3.15 MW motor in a thermal power plant application. The motor current is measured in one phase. Feature extraction is based on transient and steady state analysis. Hilbert and Wavelet transforms are used to extract broken bar features. To discuss rotor condition in time domain skewness and kurtosis of current envelope are also considered. Low shaft-load conditions are present. In case of high-voltage, high-power induction motor reliable broken bar detection is possible when contemporary digital signal processing techniques are used © 2013 IEEE.
URI: https://open.uns.ac.rs/handle/123456789/8209
ISBN: 9781479900251
DOI: 10.1109/DEMPED.2013.6645748
Nаlаzi sе u kоlеkciјаmа:FTN Publikacije/Publications

Prikаzаti cеlоkupаn zаpis stаvki

SCOPUSTM   
Nаvоđеnjа

9
prоvеrеnо 09.09.2023.