Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/8209
Назив: Broken bar detection using current analysis - A case study
Аутори: Matić, Dragan
Kanović, Željko 
Reljić, Dejan 
Kulić, Filip 
Oros, Đura 
Vasić, Veran 
Датум издавања: 1-јан-2013
Часопис: Proceedings - 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013
Сажетак: This paper covers a case study of broken bar detection for 3.15 MW motor in a thermal power plant application. The motor current is measured in one phase. Feature extraction is based on transient and steady state analysis. Hilbert and Wavelet transforms are used to extract broken bar features. To discuss rotor condition in time domain skewness and kurtosis of current envelope are also considered. Low shaft-load conditions are present. In case of high-voltage, high-power induction motor reliable broken bar detection is possible when contemporary digital signal processing techniques are used © 2013 IEEE.
URI: https://open.uns.ac.rs/handle/123456789/8209
ISBN: 9781479900251
DOI: 10.1109/DEMPED.2013.6645748