Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/32499
Назив: A Portable Device for Passive LC Sensors Readout with Low-Coupling Enhanced Sensitivity
Аутори: Mitar Simić
Adrian K. Stavrakis
Milan Radovanović 
Asif Iqbal
Varun Jeoti
Goran Stojanović 
Кључне речи: Inductive coupling;multiple measurements;mutual inductance;passive LC sensor;telemetry;resonance detection;resonance frequency
Датум издавања: 17-дец-2022
Издавач: IEEE
Пројекат: STRENTEX
Часопис: IEEE Transactions on Instrumentation and Measurement
Сажетак: Passive sensors composed of inductor L and capacitor C (LC sensors) have significant importance for applications where reliable wireless monitoring of temperature, pressure, relative humidity, strain, pH, etc. is needed. In this paper, we propose a method suitable for implementation on the portable device for wireless readout of LC sensors, which eliminates the need for costly and bulky laboratory equipment (impedance analyzers and vector network analyzers). Our approach is based on an electrical circuit of voltage divider formed by a primary inductor and a reference resistor. The resonant frequency of the LC sensor is detected from the processing of the measured voltage across the reference resistor. The readout device is realized in the form of a printed circuit board (PCB) compatible with the widely available Arduino™ boards. Wireless readout of the 10 LC tags with the proposed device and with the laboratory impedance analyzer, showed that, in frequency range 1 MHz-10 MHz, relative differences in estimated values are lower than 4%. The distinguishing feature of the presented method is its enhanced sensitivity in the case of very weak coupling between primary and sensing inductor, which was achieved using numerical differentiation approximation of the measured voltage across the reference resistor. An additional contribution of the proposed device is demonstrated with the simultaneous readout of multiple tags. Lastly, the proposed device was characterized with respect to the noise impact of the two power supply realizations (DC adapter and the battery).
URI: https://open.uns.ac.rs/handle/123456789/32499
ISSN: 0018-9456
DOI: 10.1109/TIM.2022.3232089
Права: Attribution-NonCommercial-NoDerivs 3.0 United States
Налази се у колекцијама:FTN Publikacije/Publications

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат
TIM3232089.pdf1.12 MBAdobe PDFПогледајте
Приказати целокупан запис ставки

Преглед/и станица

55
Протекла недеља
16
Протекли месец
6
проверено 10.05.2024.

Преузимање/а

33
проверено 10.05.2024.

Google ScholarTM

Проверите

Алт метрика


Ова ставка је лиценцирана под Креативна дозвола грађана Creative Commons