Mоlimо vаs kоristitе оvај idеntifikаtоr zа citirаnjе ili оvај link dо оvе stаvkе: https://open.uns.ac.rs/handle/123456789/8210
Nаziv: Induction motor broken rotor bar detection using vibration analysis - A case study
Аutоri: Kanović, Željko 
Matić, Dragan
Jeličić, Zoran 
Rapaić, Milan 
Jakovljević, Bojana
Kapetina, Mirna 
Dаtum izdаvаnjа: 1-јан-2013
Čаsоpis: Proceedings - 2013 9th IEEE International Symposium on Diagnostics for Electric Machines, Power Electronics and Drives, SDEMPED 2013
Sažetak: Early fault diagnosis and condition monitoring can reduce the consequential damage and breakdown maintenance, prolong the machine life and increase the performance of industrial systems. This paper describes a real fault detection problem of a high-power (3.2 MW) induction motor driving pumps in a heating plant. Steady-state vibration signals were collected and some characteristic low- and high- frequency features were observed, resulting in broken rotor bar diagnosis. The obtained results were verified by disassembling the motor, which proved that this particular technique can be successfully applied in induction motor fault detection. © 2013 IEEE.
URI: https://open.uns.ac.rs/handle/123456789/8210
ISBN: 9781479900251
DOI: 10.1109/DEMPED.2013.6645698
Nаlаzi sе u kоlеkciјаmа:FTN Publikacije/Publications

Prikаzаti cеlоkupаn zаpis stаvki

SCOPUSTM   
Nаvоđеnjа

23
prоvеrеnо 06.05.2023.