Nаziv: Comparison of resistive and capacitive strain gauge sensors printed on polyimide substrate using ink-jet printing technology
Аutоri: Žlebič, Čedo 
Ivanisevic N.
Kisić, Milica 
Blaz N.
Menicanin A.
Zivanov L.
Damnjanović, Mirjana 
Dаtum izdаvаnjа: 1-јан-2014
Čаsоpis: Proceedings of the International Conference on Microelectronics, ICM
Sažetak: In this paper we compared a resistive and capacitive strain gauge in terms of sensitivity and material cost, both printed with deposition material printer using silver nanoparticle ink on a flexible polyimide substrate. The resistive change due to strain was measured with a full Wheatstone bridge and a signal conditioning circuit, while the capacitance change was measured with the HP4194A impedance analyzer. Measured and derived strain gauge factor for resistive sensor was 1.10, and 0.91 for the capacitive sensor. © 2014 IEEE.