Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/6961
Title: Computer and experimental analyses of the stress state in the cement hip joint endoprosthesis body
Authors: Tabaković, Slobodan 
Grujić, Jovan
Zeljković, Milan 
Blagojević Z.
Radojević B.
Popović, Živko
Živković, Aleksandar 
Stevanović V.
Issue Date: 1-Jan-2014
Journal: Vojnosanitetski Pregled
Abstract: © 2014, Institut za Vojnomedicinske Naucne Informacije/Documentaciju. All rights reserved. Background/Aim. One of the possible complications after implantation of a cement hip-joint endoprosthesis is fracture in the endoprosthesis body. Fractures arise from overload or material fatigue of which an implant is made. The purpose of this research was to define the intensity of maximum stress and the positions of a critical cross-section in the endoprosthesis body. Methods. Unilaterally changing forces which act on the hip joint during walking as well as the loads result in flexible deformations of the endoprosthesis body. Biomechanical analysis of the forces acting on the hip joint determine their direction and intensity, whereas on the basis of Gruen’s classification of the endoprosthesis body loosening the level of fixation is established. The bodies of cement hip joint endoprosthesis are made of cobalt-chromiummolybdenum (CoCrMo) alloy, suitable for vacuum casting, are submitted to the analysis. Analysis of the critical stress in the endoprosthesis body was performed on the endoprosthesis body by means of the finite element method. The experimental verification of the obtained results was carried out on the physical prototype under laboratory conditions. Results. Computer analysis, by means of the finite element method, determined the stress state by calculation of the maximum Von Mises stress and critical cross-sections for different angles of the resultant force action. The results obtained by the computer and experimental method correlate and are comparable to the results of similar analyses conducted on various endoprosthesis types. Conclusion. The analyses described in the paper make the basis for improving the process designing of hip joint endoprostheses and their customization to each individual patient (custom made).
URI: https://open.uns.ac.rs/handle/123456789/6961
ISSN: 428450
DOI: 10.2298/vsp1411034t
Appears in Collections:FTN Publikacije/Publications

Show full item record

Page view(s)

25
Last Week
6
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.