Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке:
https://open.uns.ac.rs/handle/123456789/5370
Назив: | Application of computer-aided designing and rapid prototyping technologies in reconstruction of blowout fractures of the orbital floor | Аутори: | Tabaković, Slobodan Konstantinović V. Radosavljević R. Movrin, Dejan Hadžistević, Miodrag Hatab N. |
Датум издавања: | 1-јул-2015 | Часопис: | Journal of Craniofacial Surgery | Сажетак: | Copyright © 2015 by Mutaz B. Habal, MD. Introduction: Traumatology of the maxillofacial region represents a wide range of different types of facial skeletal injuries and encompasses numerous treatment methods. Application of computer- aided design (CAD) in combination with rapid prototyping (RP) technologies and three-dimensional computed tomography techniques facilitates surgical therapy planning for efficient treatment. Abstract: Objective: The purpose of this study is to determine the efficiency of individually designed implants of poly-DL-lactide (PDLLA) in the reconstruction of blowout fractures of the orbital floor. Methods: In the course of a surgical treatment, individually designed implants manufactured by CAD/RP technologies were used. Preoperative analysis and postoperative monitoring were conducted to evaluate the successfulness of orbital floor reconstruction using customized PDLLA implants, based on: presence of diplopia, paresthesia of infraorbital nerve, and presence of enophthalmos. Results: In 6 of the 10 patients, diplopia completely disappeared immediately after surgical procedure. Diplopia gradually disappeared after 1 month in 3 patients, whereas in 1, it remained even after 6 months. In 7 patients, paresthesia disappeared within a month after surgery and in 3 patients within 2 months. Postoperative average Orbital volume (OV) of the injured side (13.333±3.177) was significantly reduced in comparison with preoperative OV (15.847±3.361) after reconstruction of the orbital floor with customized PDLLA implant (P<0.001). Thus, average OV of corrected orbit was not different compared with the OV of the uninjured orbit (P=0.981). Conclusions: Reconstruction of blowout fractures of the orbital floor by an individually designed PDLLA implant combined with virtual preoperative modeling allows easier preoperative preparation and yields satisfactory functional and esthetic outcomes. | URI: | https://open.uns.ac.rs/handle/123456789/5370 | ISSN: | 10492275 | DOI: | 10.1097/SCS.0000000000001883 |
Налази се у колекцијама: | FTN Publikacije/Publications |
Приказати целокупан запис ставки
SCOPUSTM
Навођења
19
проверено 10.05.2024.
Преглед/и станица
30
Протекла недеља
6
6
Протекли месец
4
4
проверено 10.05.2024.
Google ScholarTM
Проверите
Алт метрика
Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.