Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/5370
Назив: Application of computer-aided designing and rapid prototyping technologies in reconstruction of blowout fractures of the orbital floor
Аутори: Tabaković, Slobodan 
Konstantinović V.
Radosavljević R.
Movrin, Dejan 
Hadžistević, Miodrag 
Hatab N.
Датум издавања: 1-јул-2015
Часопис: Journal of Craniofacial Surgery
Сажетак: Copyright © 2015 by Mutaz B. Habal, MD. Introduction: Traumatology of the maxillofacial region represents a wide range of different types of facial skeletal injuries and encompasses numerous treatment methods. Application of computer- aided design (CAD) in combination with rapid prototyping (RP) technologies and three-dimensional computed tomography techniques facilitates surgical therapy planning for efficient treatment. Abstract: Objective: The purpose of this study is to determine the efficiency of individually designed implants of poly-DL-lactide (PDLLA) in the reconstruction of blowout fractures of the orbital floor. Methods: In the course of a surgical treatment, individually designed implants manufactured by CAD/RP technologies were used. Preoperative analysis and postoperative monitoring were conducted to evaluate the successfulness of orbital floor reconstruction using customized PDLLA implants, based on: presence of diplopia, paresthesia of infraorbital nerve, and presence of enophthalmos. Results: In 6 of the 10 patients, diplopia completely disappeared immediately after surgical procedure. Diplopia gradually disappeared after 1 month in 3 patients, whereas in 1, it remained even after 6 months. In 7 patients, paresthesia disappeared within a month after surgery and in 3 patients within 2 months. Postoperative average Orbital volume (OV) of the injured side (13.333±3.177) was significantly reduced in comparison with preoperative OV (15.847±3.361) after reconstruction of the orbital floor with customized PDLLA implant (P<0.001). Thus, average OV of corrected orbit was not different compared with the OV of the uninjured orbit (P=0.981). Conclusions: Reconstruction of blowout fractures of the orbital floor by an individually designed PDLLA implant combined with virtual preoperative modeling allows easier preoperative preparation and yields satisfactory functional and esthetic outcomes.
URI: https://open.uns.ac.rs/handle/123456789/5370
ISSN: 10492275
DOI: 10.1097/SCS.0000000000001883
Налази се у колекцијама:FTN Publikacije/Publications

Приказати целокупан запис ставки

SCOPUSTM   
Навођења

19
проверено 10.05.2024.

Преглед/и станица

30
Протекла недеља
6
Протекли месец
4
проверено 10.05.2024.

Google ScholarTM

Проверите

Алт метрика


Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.