Назив: Lack of concordance amongst measurements of individual anaerobic threshold and maximal lactate steady state on a cycle ergometer
Аутори: Arratibel-Imaz, Iñaki
Calleja-González, Julio
Emparanza, Jose Ignacio
Terrados, Nicolas
Mjaanes, Jeffrey M.
Ostojić, Sergej 
Кључне речи: IAT;MLSS;OBLA;Lactate;Cycle ergometer
Датум издавања: 2016
Часопис: Physician and Sportsmedicine
Сажетак: Introduction: The calculation of exertion intensity, in which a change is produced in the metabolic processes which provide the energy to maintain physical work, has been defined as the anaerobic threshold (AT). The direct calculation of maximal lactate steady state (MLSS) would require exertion intensities over a long period of time and with sufficient rest periods which would prove significantly difficult for daily practice. Many protocols have been used for the indirect calculation of MLSS. Objectives: The aim of this study is to determine if the results of measurements with 12 different AT calculation methods and calculation software [Keul, Simon, Stegmann, Bunc, Dickhuth (TKM and WLa), Dmax, Freiburg, Geiger-Hille, Log-Log, Lactate Minimum] can be used interchangeably, including the method of the fixed threshold of Mader/OBLA’s 4 mmol/l and then to compare them with the direct measurement of MLSS. Methods: There were two parts to this research. Phase 1: results from 162 exertion tests chosen at random from the 1560 tests. Phase 2: sixteen athletes (n = 16) carried out different tests on five consecutive days. Results: There was very high concordance among all the methods [intraclass correlation coefficient (ICC) > 0.90], except Log-Log in relation to the Stegamnn, Dmax, Dickhuth-WLa and Geiger-Hille. The Dickhuth-TKM showed a high tendency towards concordance, with Dmax (2.2 W) and Dickhuth-WLa (0.1 W). The Dickhuth-TKM method presented a high tendency to concordance with Dickhuth-WLa (0.5 W), Freiburg (7.4 W), MLSS (2.0 W), Bunc (8.9 W), Dmax (0.1 W). The calculation of MLSS power showed a high tendency to concordance, with Dickhuth-TKM (2 W), Dmax (2.1 W), Dickhuth-WLa (1.5 W). Conclusion: The fixed threshold of 4 mmol/l or OBLA produces slightly different and higher results than those obtained with all the methods analyzed, including MLSS, meaning an overestimation of power in the individual anaerobic threshold. The Dickhuth-TKM, Dmax and Dickhuth-WLa methods defined a high concordance on a cycle ergometer. Dickhuth-TKM, Dmax, Dickhuth-WLa described a high concordance with the power calculated to know the MLSS.
URI: https://open.uns.ac.rs/handle/123456789/5243
ISSN: 0091-3847
DOI: 10.1080/00913847.2016.1122501
Налази се у колекцијама:FSFV Publikacije/Publications

Приказати целокупан запис ставки

SCOPUSTM   
Навођења

15
проверено 10.05.2024.

Преглед/и станица

33
Протекла недеља
7
Протекли месец
0
проверено 10.05.2024.

Google ScholarTM

Проверите

Алт метрика


Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.