Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/5243
Title: Lack of concordance amongst measurements of individual anaerobic threshold and maximal lactate steady state on a cycle ergometer
Authors: Arratibel-Imaz, Iñaki
Calleja-González, Julio
Emparanza, Jose Ignacio
Terrados, Nicolas
Mjaanes, Jeffrey M.
Ostojić, Sergej 
Keywords: IAT;MLSS;OBLA;Lactate;Cycle ergometer
Issue Date: 2016
Journal: Physician and Sportsmedicine
Abstract: Introduction: The calculation of exertion intensity, in which a change is produced in the metabolic processes which provide the energy to maintain physical work, has been defined as the anaerobic threshold (AT). The direct calculation of maximal lactate steady state (MLSS) would require exertion intensities over a long period of time and with sufficient rest periods which would prove significantly difficult for daily practice. Many protocols have been used for the indirect calculation of MLSS. Objectives: The aim of this study is to determine if the results of measurements with 12 different AT calculation methods and calculation software [Keul, Simon, Stegmann, Bunc, Dickhuth (TKM and WLa), Dmax, Freiburg, Geiger-Hille, Log-Log, Lactate Minimum] can be used interchangeably, including the method of the fixed threshold of Mader/OBLA’s 4 mmol/l and then to compare them with the direct measurement of MLSS. Methods: There were two parts to this research. Phase 1: results from 162 exertion tests chosen at random from the 1560 tests. Phase 2: sixteen athletes (n = 16) carried out different tests on five consecutive days. Results: There was very high concordance among all the methods [intraclass correlation coefficient (ICC) > 0.90], except Log-Log in relation to the Stegamnn, Dmax, Dickhuth-WLa and Geiger-Hille. The Dickhuth-TKM showed a high tendency towards concordance, with Dmax (2.2 W) and Dickhuth-WLa (0.1 W). The Dickhuth-TKM method presented a high tendency to concordance with Dickhuth-WLa (0.5 W), Freiburg (7.4 W), MLSS (2.0 W), Bunc (8.9 W), Dmax (0.1 W). The calculation of MLSS power showed a high tendency to concordance, with Dickhuth-TKM (2 W), Dmax (2.1 W), Dickhuth-WLa (1.5 W). Conclusion: The fixed threshold of 4 mmol/l or OBLA produces slightly different and higher results than those obtained with all the methods analyzed, including MLSS, meaning an overestimation of power in the individual anaerobic threshold. The Dickhuth-TKM, Dmax and Dickhuth-WLa methods defined a high concordance on a cycle ergometer. Dickhuth-TKM, Dmax, Dickhuth-WLa described a high concordance with the power calculated to know the MLSS.
URI: https://open.uns.ac.rs/handle/123456789/5243
ISSN: 0091-3847
DOI: 10.1080/00913847.2016.1122501
Appears in Collections:FSFV Publikacije/Publications

Show full item record

SCOPUSTM   
Citations

15
checked on May 3, 2024

Page view(s)

32
Last Week
7
Last month
0
checked on May 3, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.