Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/3956
Назив: Broken bar fault detection in IM operating under no-load condition
Аутори: Reljić, Dejan 
Jerkan, Dejan 
Marčetić, Darko 
Oros, Đura
Датум издавања: 1-јан-2016
Часопис: Advances in Electrical and Computer Engineering
Сажетак: © 2016 AECE. This paper presents a novel method for broken rotor bar detection in a squirrel-cage induction motor (IM). The proposed method applies a single-phase AC voltage as a test signal on motor terminals, resulting in a stator backwardrotating magnetic field. The field ultimately causes additional current components in the stator windings whose magnitudes depend on the broken bar fault severity, even if the motor is unloaded. This allows robust broken bar fault detection based only on standard motor current signature analysis (MCSA) technique. The proposed fault detection method is at first verified via simulations, using an IM model based on finite element analysis (FEA) and multiple coupled circuit approach (MCCA). The subsequent experimental investigations have shown good agreement with both theoretical predictions and simulation results.