Title: | Application of current transformer for normal magnetization curve determination | Authors: | Herceg, Dejana Kasaš-Lažetić, Karolina Antić, Danka Bjelica, Jelena Prša M. |
Issue Date: | 27-Dec-2016 | Journal: | 2016 International Symposium on Industrial Electronics, INDEL 2016 - Proceedings | Abstract: | © 2016 IEEE. Determination of normal magnetization curve is a well known problem, solved and described in many papers. But none of the normal magnetization curve measurements were performed applying current transformer instead of voltage toroidal transformer sample. Comparing the application of current transformer versus the application of voltage transformer, several different procedures and approaches appeared. All these procedures, together with the appropriate solutions and results were presented in this paper. The results presented in the paper show that current transformer can also be successfully applied for an accurate normal dynamic magnetization curve determination. | URI: | https://open.uns.ac.rs/handle/123456789/3839 | ISBN: | 9781509023295 | DOI: | 10.1109/INDEL.2016.7797816 |