Nаziv: The ABM 8057 utilization for SEMONT's EMF monitoring in a closed room
Аutоri: Kundacina O.
Vincan V.
Antić, Danka 
Kljajić, Dragan 
Kasaš-Lažetić, Karolina 
Dаtum izdаvаnjа: 13-јан-2017
Čаsоpis: 24th Telecommunications Forum, TELFOR 2016
Sažetak: © 2016 IEEE. The Serbian Electromagnetic Field Monitoring Network - SEMONT has started with test monitoring of electromagnetic field (EMF) in a closed room. In this paper, the case study of the high-frequency electric field strength monitoring is presented, utilizing Narda AMB 8057/03 monitoring station. The monitoring procedure has been simultaneously performed in frequency ranges of 100 kHz-7 GHz, GSM 900, GSM 1800 and UMTS 2100, in a closed room of largest amphitheater of the Faculty of Technical Science, University of Novi Sad. The monitoring was conducted during real daily conditions and student's presence inside of the amphitheater, showing that the high-frequency electric field strength values are far below the Serbian's prescribed reference levels.