Mоlimо vаs kоristitе оvај idеntifikаtоr zа citirаnjе ili оvај link dо оvе stаvkе: https://open.uns.ac.rs/handle/123456789/32709
Nаziv: Femtomolar detection of the heart failure biomarker NT-proBNP in artificial saliva using an immersible liquid-gated aptasensor with reduced graphene oxide
Аutоri: Jarić, Stefan 
Kudriavtseva, Anastasiia
Nekrasov, Nikita
Orlov, Alexey
Komarov, Ivan
Barsukov, Leonty
Gađanski, Ivana 
Nikitin, Petr
Bobrinetskiy, Ivan 
Dаtum izdаvаnjа: јан-2024
Izdаvаč: Elsevier
Prојеkаt: Antares 
Čаsоpis: Microchemical Journal
Sažetak: Measuring NT-proBNP biomarker is recommended for preliminary diagnostics of the heart failure. Recent studies suggest a possibility of early screening of biomarkers in saliva for non-invasive identification of cardiac diseases at the point-of-care. However, NT-proBNP concentrations in saliva can be thousand time lower than in blood plasma, going down to pg/mL level. To reach this level, we developed a label-free aptasensor based on a liquid-gated field effect transistor using a film of reduced graphene oxide monolayer (rGO-FET) with immobilized NT-proBNP specific aptamer. We found that, depending on ionic strength of tested solutions, there were different levels of correlation in responses of electrical parameters of the rGO-FET aptasensor, namely, the Dirac point shift and transconductance change. The correlation in response to NT-proBNP was high for 1.6 mM phosphate-buffered saline (PBS) and zero for 16 mM PBS in a wide range of analyte concentrations, varied from 1 fg/mL to 10 ng/mL. The effects of transconductance and Dirac point shift in PBS solutions of different concentrations are discussed. The biosensor exhibited a high sensitivity for both transconductance (2 µS/decade) and Dirac point shift (2.3 mV/decade) in diluted PBS with the linear range from 10 fg/mL to 1 pg/mL. The aptasensor performance has been also demonstrated in undiluted artificial saliva with the achieved limit of detection down to 41 fg/mL (∼4.6 fM).
URI: https://open.uns.ac.rs/handle/123456789/32709
ISSN: 0026-265X
DOI: 10.1016/j.microc.2023.109611
Nаlаzi sе u kоlеkciјаmа:IBS Publikacije/Publications

Dаtоtеkе u оvој stаvci:
Dаtоtеkа VеličinаFоrmаt
Femtomolar detection of the heart failure.pdf3.85 MBAdobe PDFPоglеdајtе
Prikаzаti cеlоkupаn zаpis stаvki

Prеglеd/i stаnicа

29
prоvеrеnо 03.05.2024.

Google ScholarTM

Prоvеritе

Аlt mеtrikа


Stаvkе nа DSpace-u su zаštićеnе аutоrskim prаvimа, sа svim prаvimа zаdržаnim, оsim аkо nije drugačije naznačeno.