Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/32452
Назив: Influence of fluorine-containing mouthwashes on NiTi Alloy corrosion
Аутори: Zoran Bobić
Bojan Petrović 
Sanja Kojić 
Vladimir Terek 
Branko Škorić 
Lazar Kovačević 
Goran Stojanović 
Pal Terek 
Кључне речи: biomaterial;NiTi;corrosion;AFM;nano topography;ANOVA;paired T-test
Датум издавања: 14-окт-2021
Издавач: University of Kragujevac
Пројекат: H2020 SALSETH
Конференција: 38th International Conference on Production Engineering –Serbia, ICPE-S 2021
Сажетак: Evaluation of NiTi alloy corrosion behaviour in fluorine-containing media still remains a great characterization challenge. Such characterization is commonly simplified by using aggressive media with a high concentration of fluorine. Accordingly, the difficulties in the characterization of material changes on a nano-level are avoided. However, these results do not sufficiently resemble the real situation. Therefore, the motivation of this work was to perform a non-accelerated corrosion test, characterize the nano topographic changes, and to evaluate the obtained results by statistical methods. In this study, we examined the behaviour of NiTi alloy archwires exposed for 21 days to artificial saliva and fluorine-containing mouthwash Aquafresh My Big teeth®. Atomic force microscope (AFM) Veeco CP-II, and scanning electron microscope (SEM) Hitachi TM3030, were employed for characterization of changes in surface topography, on the areas of 80x80 and 10x10 μm. Before and after the corrosion tests specimens were evaluated at 5 locations of 80x80 μm. Topographic images were analysed by image analysis software (Spip 6.2.0) and surface roughness parameters (Sa and S10z) were calculated. The changes in chemical composition were evaluated by energy-dispersive X-ray spectroscopy (EDS). Paired T-test and one-way ANOVA statistical analysis were employed for the evaluation of the changes observed in surface roughness parameters and chemical composition. Changes in surface topography observed in AFM and SEM images (80x80 μm) are negligible for both specimens. Analysis of AFM topographic images (10x10 μm) revealed that only specimen exposed to Aquafresh My Big teeth® exhibited nano changes in surface topography. For artificial saliva negligible changes were observed, while Aquafresh My Big teeth® exhibited notable changes in Sa and S10z parameters. Statistical analysis of data revealed that changes in roughness parameters are significant only for specimens exposed to Aquafresh My Big teeth® ®. This indicates that the presence of fluorine in mouthwash increases the NiTi corrosion. Statistical analysis methods and AFM have been proven as a valuable tool in the characterization of nano topographic changes caused by corrosion in real conditions.
URI: https://open.uns.ac.rs/handle/123456789/32452
Права: Attribution-NonCommercial-NoDerivs 3.0 United States
Налази се у колекцијама:FTN Publikacije/Publications

Датотеке у овој ставци:
Датотека Опис ВеличинаФормат
Bobić Zoran el al. ICPE-S 2021 paper.pdf542.41 kBAdobe PDFПогледајте
Приказати целокупан запис ставки

Преглед/и станица

39
Протекла недеља
3
Протекли месец
4
проверено 10.05.2024.

Преузимање/а

28
проверено 10.05.2024.

Google ScholarTM

Проверите


Ова ставка је лиценцирана под Креативна дозвола грађана Creative Commons