Nаziv: | Comprehensive Review on Wearable Sweat-Glucose Sensors for Continuous Glucose Monitoring | Аutоri: | Hima Zafar Asma Channa Varun Jeoti Goran Stojanović |
Ključnе rеči: | biosensor;diabetes;hypoglycemia;sweat based sensing;wearable electronics;non-invasive glucose monitoring | Dаtum izdаvаnjа: | 15-јан-2022 | Izdаvаč: | MDPI | Prојеkаt: | STRENTEX | Čаsоpis: | Sensors | Sažetak: | The incidence of diabetes is increasing at an alarming rate, and regular glucose monitoring is critical in order to manage diabetes. Currently, glucose in the body is measured by an invasive method of blood sugar testing. Blood glucose (BG) monitoring devices measure the amount of sugar in a small sample of blood, usually drawn from pricking the fingertip, and placed on a disposable test strip. Therefore, there is a need for non-invasive continuous glucose monitoring, which is possible using a sweat sensor-based approach. As sweat sensors have garnered much interest in recent years, this study attempts to summarize recent developments in non-invasive continuous glucose monitoring using sweat sensors based on different approaches with an emphasis on the devices that can potentially be integrated into a wearable platform. Numerous research entities have been developing wearable sensors for continuous blood glucose monitoring, however, there are no commercially viable, non-invasive glucose monitors on the market at the moment. This review article provides the state-of-the-art in sweat glucose monitoring, particularly keeping in sight the prospect of its commercialization. The challenges relating to sweat collection, sweat sample degradation, person to person sweat amount variation, various detection methods, and their glucose detection sensitivity, and also the commercial viability are thoroughly covered. | URI: | https://open.uns.ac.rs/handle/123456789/32435 | ISSN: | 1424-8220 | DOI: | https://doi.org/10.3390/s22020638 | Prаvа: | Attribution-NonCommercial 3.0 United States |
Nаlаzi sе u kоlеkciјаmа: | FTN Publikacije/Publications |
Dаtоtеkе u оvој stаvci:
Dаtоtеkа | Оpis | Vеličinа | Fоrmаt | |
---|---|---|---|---|
sensors-22-00638.pdf | 17.74 MB | Adobe PDF | Pоglеdајtе |
Prеglеd/i stаnicа
54
Prоtеklа nеdеljа
10
10
Prоtеkli mеsеc
6
6
prоvеrеnо 10.05.2024.
Prеuzimаnjе/а
32
prоvеrеnо 10.05.2024.
Google ScholarTM
Prоvеritе
Аlt mеtrikа
Оvа stаvkа је licеncirаnа pоd Krеаtivnа dоzvоlа grаđаnа