Nаziv: | The study of copper corrosion in the presence of selected triazole derivatives Proučavanje korozije bakra u prisustvu odabranih derivata tiazola |
Аutоri: | Nakomčić Jelena | Ključnе rеči: | copper corrosion, thiazoles, corrosion inhibitors, corrosion measurement;korozija bakra, tiazoli, inhibitori korozije, koroziona merenja | Dаtum izdаvаnjа: | 8-дец-2016 | Izdаvаč: | Univerzitet u Novom Sadu, Prirodno-matematički fakultet u Novom Sadu University of Novi Sad, Faculty of Sciences at Novi Sad |
Sažetak: | <p>U ovom radu efikasnost odabranih derivata tiazola u inhibiciji korozije bakra u kiseloj<br />sulfatnoj sredini određena je u funkciji koncentracije inhibitora metodom merenja<br />gubitka mase, elektrohemijskom impedansnom spektroskopijom i potenciostatskom<br />polarizacijom. Polarizacionim merenjima takođe je određena zavisnost inhibitorske<br />efikasnosti od temperature i kinetički parametri procesa korozije bakra kao i model<br />adsorpcione izoterme prema kojem se odigrava proces adsorpcije inhibitora i odgovarajući termodinamički parametri. Merenjima kvarc kristalnom mikrovagom <em>in </em><br /><em>situ </em>je praćen proces elektrohemijskog rastvaranja bakra i adsorpcije ispitivanih<br />inhibitora. SEM/EDX analizom proučavana je promena morfologije bakarne površine<br />usled dejstva korozione sredine i rastvora inhibitora. Rezultati eksperimentalnih<br />ispitivanja korelirani su sa teorijskim proračunima na nivou teorije funkcionala<br />gustine.</p> <p>In this work, the efficiency of selected thiazole derivatives in the inhibition of corrosion of copper in the acidic sulfate solution is determined in the function ofthe inhibitors concentration by weight loss method, electrochemical impedance spectroscopy and potentiostatic polarization. The dependence of the inhibition efficiency of temperature and kinetic parameters of the process of corrosion ofcopper as well as adsorption isotherm model according to which takes place the process of adsorption of inhibitors and the corresponding thermodynamic parameters were also determined by polarization measurements. A process of electrochemical copper dissolution and adsorption of tested inhibitors is followedin situ by quartz crystal microbalance measurements Changes in the morphology of the copper surface due to the effects of corrosive environment and the solutions of the inhibitors were studied by SEM/EDX analysis.The experimental results were correlated with theoretical calculations at the density functional theory level.</p> |
URI: | https://open.uns.ac.rs/handle/123456789/16913 |
Nаlаzi sе u kоlеkciјаmа: | PMF Teze/Theses |
Prikаzаti cеlоkupаn zаpis stаvki
Prеglеd/i stаnicа
9
Prоtеklа nеdеljа
7
7
Prоtеkli mеsеc
0
0
prоvеrеnо 10.05.2024.
Google ScholarTM
Prоvеritе
Stаvkе nа DSpace-u su zаštićеnе аutоrskim prаvimа, sа svim prаvimа zаdržаnim, оsim аkо nije drugačije naznačeno.