Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/14247
Title: Accuracy limit of high-precision stochastic watt-hour meter
Authors: Pejić, Dragan 
Vujičić, Vladimir
Issue Date: 1-Jan-2000
Journal: IEEE Transactions on Instrumentation and Measurement
Abstract: This paper deals with the practical application of the newly developed stochastic watt-hour meter. The limit of its precision is analyzed theoretically, via simulation, and experimentally. The precision of 0.0062% is achieved in the laboratory experiment. Field experiments also confirm good application properties of the device.
URI: https://open.uns.ac.rs/handle/123456789/14247
ISSN: 00189456
DOI: 10.1109/19.850404
Appears in Collections:FTN Publikacije/Publications

Show full item record

SCOPUSTM   
Citations

36
checked on Nov 20, 2023

Page view(s)

11
Last Week
7
Last month
0
checked on May 3, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.