Назив: Computer as a tool for controlling measurement of water content in building materials
Аутори: Radovanović M.
Stojanović, Goran 
Blaž N.
Датум издавања: 27-јул-2011
Часопис: EUROCON 2011 - International Conference on Computer as a Tool - Joint with Conftele 2011
Сажетак: This paper describes the application of wireless LC sensor for measuring the concentration of water (or moisture) in the building materials. The sensor has manufactured on a double layered PCB (Printed Circuit Board) and placed in a test Sample of a building material that is immersed in water. The change of water concentration in the Sample can be measured wirelessly (antenna coil) by monitoring variations in sensors resonant frequency. Clay brick and aerated autoclaved concrete block are used for examination and testing as the often used building materials. Dielectric constant of water is much higher comPared to the dielectric constant of test Samples, and the higher concentration of water (or moisture) content of Samples dictated a reduction in the sensor resonant frequency. Measurements were done at room temperature, using a PC with in-house developed software and an Impedance Analyzer HP-4194A. The program has been developed in LabVIEW software package allowing remote control and acquisition of measured data. © 2011 IEEE.
URI: https://open.uns.ac.rs/handle/123456789/13666
ISBN: 9781424474868
DOI: 10.1109/EUROCON.2011.5929257
Налази се у колекцијама:FTN Publikacije/Publications

Приказати целокупан запис ставки

SCOPUSTM   
Навођења

1
проверено 10.05.2024.

Преглед/и станица

33
Протекла недеља
8
Протекли месец
0
проверено 10.05.2024.

Google ScholarTM

Проверите

Алт метрика


Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.