Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке:
https://open.uns.ac.rs/handle/123456789/12243
Назив: | Scanning electron microscopy investigation of canal cleaning after canal preparation with nickel titanium files | Аутори: | Tatjana Brkanić Ivana Stojšin Karolina Vukoje Slavoljub Živković |
Кључне речи: | root canal preparation;scanning electron microscopy;smear layer;nickel;preparacija kanala korena zuba;skening-elektronska mikroskopija (SEM);razmazni sloj;nikl;titanijum;titanium | Датум издавања: | 1-дец-2010 | Часопис: | Srpski Arhiv za Celokupno Lekarstvo | Сажетак: | Introduction: Root canal preparation is the most important phase of endodontic procedure and it consists of adequate canal space cleaning and shaping. In recent years, rotary instruments and techniques have gained importance because of the great efficacy, speed and safety of the preparation procedure. Objective: The aim of this research was to investigate the influence of different NiTi files on the canal wall cleaning quality, residual dentine debris and smear layer. Methods: The research was conducted on extracted human teeth in vitro conditions. Teeth were divided in 7 main groups depending on the kind of instruments used for root canal preparation: ProTaper, GT, ProFile, K-3, FlexMaster, hand ProTaper and hand GT. Root canal preparation was accomplished by crown-down technique. Prepared samples were assessed on scanning electron microscopy JEOL, JSM-6460 LV. The evaluation of dentine debris was done with 500x magnification, and the evaluation of smear layer with 1,000 times magnification. Quantitive asessment of dentine debris and smear layer was done according to the criteria of Hulsmann. Results: The least amount of debris and smear layer has been found in canals shaped with ProFile instruments, and the largest amount in canals shaped with FlexMaster instruments. Canal cleaning efficacy of hand GT and ProTaper files has been similar to cleaning efficacy of rotary NiTi files. Statistic analysis has shown a significant difference in amount of dentine debris and smear layer on the canal walls between sample groups shaped with different instruments. Conclusion: Completely clean canals have not been found in any tested group of instruments. The largest amount of debris and smear layer has been found in the apical third of all canals. The design and the type of endodontic instruments influence the efficacy of the canal cleaning. | URI: | https://open.uns.ac.rs/handle/123456789/12243 | ISSN: | 3708179 | DOI: | 10.2298/SARH1010551B |
Налази се у колекцијама: | MDF Publikacije/Publications |
Приказати целокупан запис ставки
SCOPUSTM
Навођења
3
проверено 10.05.2024.
Преглед/и станица
33
Протекла недеља
9
9
Протекли месец
0
0
проверено 10.05.2024.
Google ScholarTM
Проверите
Алт метрика
Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.