Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/1214
Назив: Low Resolution Stochastic Flash ADC for High Precision Energy and RMS Voltage Measurements for Smart Grid
Аутори: Urekar, Marjan 
Pejić, Dragan
Датум издавања: 19-окт-2018
Часопис: CPEM 2018 - Conference on Precision Electromagnetic Measurements
Сажетак: © 2018 IEEE. This paper describes 4-bit Stochastic Flash ADC based instrument, with its low-resolution compensated by adding dither (uniform noise) to the input signal and calculation of the output average value over a finite time period, resulting in low part count, high sampling speed and low error. Precision of this instrument is user controlled-the longer the period of measurement, higher the measurement precision. This enables measurement of electrical quantities over long time intervals, such as electrical energy and RMS voltage in a power grid. For 60-second measurement period, precision is 58 ppm, and for 180 s it is 34 ppm.
URI: https://open.uns.ac.rs/handle/123456789/1214
ISBN: 9781538609736
DOI: 10.1109/CPEM.2018.8501106
Налази се у колекцијама:FTN Publikacije/Publications

Приказати целокупан запис ставки

SCOPUSTM   
Навођења

2
проверено 29.04.2023.

Преглед/и станица

20
Протекла недеља
7
Протекли месец
0
проверено 10.05.2024.

Google ScholarTM

Проверите

Алт метрика


Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.