Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/11237
Title: Influence of sintering temperature on complex permeability of ferritic LTCC in wide frequency range
Authors: Marić, Andrea 
Atassi I.
Blaž, Nelu
Radosavljević, Goran
Živanov, Ljiljana
Homolka H.
Smetana W.
Nicolics J.
Issue Date: 12-Dec-2011
Journal: Proceedings of the International Spring Seminar on Electronics Technology
Abstract: The complex permeability values of commercially available ferrite LTCC tapes (Low Temperature Cofired Ceramics) in dependence on firing peak temperature have been for the first time determined in the high-frequency range (300 kHz - 1 GHz). Grain size growth due to higher firing peak temperature is compared to the change of the complex permeability. Permeability values have been calculated from S-parameters measured with a vector network analyzer and a short coaxial sample holder into which ferritic LTCC toroids have been placed. The toroids were realized by stacking and laminating 62 layers of green tape and then sintered at peak temperatures of 885°C, 1000°C and 1100°C, respectively. The maximum relative permeability values increase up to 900 (at 1100°C firing peak temperature) and show a shift to lower frequency values. © 2011 IEEE.
URI: https://open.uns.ac.rs/handle/123456789/11237
ISBN: 9781457721120
ISSN: 21612528
DOI: 10.1109/ISSE.2011.6053884
Appears in Collections:FTN Publikacije/Publications

Show full item record

Page view(s)

10
Last Week
7
Last month
0
checked on May 3, 2024

Google ScholarTM

Check

Altmetric