Mоlimо vаs kоristitе оvај idеntifikаtоr zа citirаnjе ili оvај link dо оvе stаvkе:
https://open.uns.ac.rs/handle/123456789/9487
Nаziv: | Trace determination of Carbendazim fungicide using adsorptive stripping voltammetry with a carbon paste electrode containing tricresyl phosphate | Аutоri: | Ashrafi A. Đorđević, Jasmina Guzvanj (Guzsvány), Valerija (Valéria) Švancara I. Trtić-Petrović T. Purenović M. Vytřas K. |
Dаtum izdаvаnjа: | 1-дец-2012 | Čаsоpis: | International Journal of Electrochemical Science | Sažetak: | In this study, a carbon paste electrode based on tricresyl phosphate (TCP-CPE) as a binder has been applied to the voltammetric characterization and determination of Carbendazim fungicide (methyl-1H-benzimidazol-2-yl-carbamate, MBC). The pH effect (in Britton-Robinson buffers, pH 2.0-8.0), as well as the presence of 2-hydroxypropyl-β-cyclodextrin (HPCD) on the electrochemical behavior of MBC were investigated. In the potential range of interest, the oxidation signal was observed with the overall shape strongly dependent upon pH and exhibiting the most favorable signal-to-noise ratio in mild acidic solutions (pH 4.0). This has indicated that also protons are involved in the electrode transformation of MBC. Furthermore, it was confirmed that addition of 3.6·10-5 mol L-1 HPCD significantly enhanced the sensitivity towards the target analyte. The experimental conditions optimised for the determination of MBC in the differential pulse adsorptive stripping voltammetric mode (DPAdSV) were as follows: initial potential, -0.10 V vs. Ag/AgCl; final potential, +1.30 V; accumulation potential, -0.35 V; accumulation time, 120 s, and the scan rate, 100 mV s-1. The method developed offers linearity in the concentration range of 5.0 ·10-7 - 1.0·10-5 mol L-1 MBC, with r = 0.995 and the limit of detection of about 3.0·10-7 mol L-1. In a model sample of spiked river water, the recovery rate achieved was 101.9 % (at the concentrations from 1.0·10-6 to 3.0·10-6 mol L-1 MBC), suggesting one that the procedure can be applied in analysis of real samples. © 2012 by ESG. | URI: | https://open.uns.ac.rs/handle/123456789/9487 |
Nаlаzi sе u kоlеkciјаmа: | PMF Publikacije/Publications |
Prikаzаti cеlоkupаn zаpis stаvki
SCOPUSTM
Nаvоđеnjа
28
prоvеrеnо 22.02.2020.
Prеglеd/i stаnicа
39
Prоtеklа nеdеljа
1
1
Prоtеkli mеsеc
0
0
prоvеrеnо 10.05.2024.
Google ScholarTM
Prоvеritе
Stаvkе nа DSpace-u su zаštićеnе аutоrskim prаvimа, sа svim prаvimа zаdržаnim, оsim аkо nije drugačije naznačeno.