Назив: Possibility of improvement of boiler water treatment process-ion exchange vs. reverse osmosis
Аутори: Kukić, Dragana 
Šćiban, Marina 
Mitrović, Branka
Prodanović, Jelena 
Vasić, Vesna 
Ivetić, Darjana
Antov, Mirjana 
Датум издавања: 2013
Издавач: Taylor & Francis Group
Часопис: Desalination and Water Treatment
Сажетак: The boiler water in certain power plant is produced by chemical decarbonization, sand filtration, and ion exchange. Process ends with mixed bed ion exchange. The current boiler water treatment process is analyzed in terms of achieved water quality, quantity and quality of wastewater, and amount of chemicals needed. The main disadvantage of current process is consumption of large amount of chemicals. Ion exchange process could be replaced with the reverse osmosis, but pretreatment (decarbonization and filtration) should be retained. Since the permeate quality does not meet quality requirements, it would be advisable to use mixed bed ion exchange. If reverse osmosis is used, quantity of water that enters the treatment and wastewater would be for about 17.5 and 150% larger, respectively, but content of salt in wastewater would be about 20-30-fold less. Nevertheless, final decision on which technique to apply should be based on further economical considerations. © 2013 Desalination Publications.
URI: https://open.uns.ac.rs/handle/123456789/9200
ISSN: 19443994
DOI: 10.1080/19443994.2012.714860
Налази се у колекцијама:TF Publikacije/Publications

Приказати целокупан запис ставки

SCOPUSTM   
Навођења

4
проверено 03.05.2024.

Преглед/и станица

44
Протекла недеља
11
Протекли месец
0
проверено 10.05.2024.

Google ScholarTM

Проверите

Алт метрика


Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.