Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/8979
DC FieldValueLanguage
dc.contributor.authorBabković, Kalmanen_US
dc.contributor.authorNađ, Lasloen_US
dc.contributor.authorKrklješ, Damiren_US
dc.date.accessioned2019-09-30T09:12:36Z-
dc.date.available2019-09-30T09:12:36Z-
dc.date.issued2013-
dc.identifier.isbn9783037856161en_US
dc.identifier.issn10139826en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/8979-
dc.description.abstractCommercially available reflective optical sensors can be used as displacement sensors which in turn can be used in vibration monitoring, positioning, force-measurement and other applications. The sensor output depends in all cases on the distance between the component and a suitable reflective surface. In this paper a sensor system applicable to vibration measurement (e.g. monitoring a vibration-generating machine mounted on elastic isolation mountings) is presented where a special mechanism enables the controlled adjustment of the reflective surface's position. This feature allows continuous operating point adjustment while the sensor measures vibration. On the other hand, during the intervals when the vibration measurement is not active (e.g. the machine is not in use), the system can be used to automatically calibrate the sensor, i.e. to measure the dependence of the optical sensor output from the distance to the reflective surface. This allows accurate measurements under various circumstances: temperature change, optical component replacement, staining of the reflective surface, ingress of dirt etc. The reflective surface adjustment system is controlled by an embedded digital system which also controls the calibration procedure. Range depends largely on the type of reflective sensor. In case of the component TCRT1000 used in the experiments, range is up to 4 mm. © (2013) Trans Tech Publications.en
dc.relation.ispartofKey Engineering Materialsen
dc.titleSelf-calibrating optical displacement sensoren_US
dc.typeConference Paperen_US
dc.identifier.doi10.4028/www.scientific.net/KEM.543.59-
dc.identifier.scopus2-s2.0-84876386202-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/84876386202-
dc.description.versionUnknownen_US
dc.relation.lastpage62en
dc.relation.firstpage59en
dc.relation.volume543en
item.grantfulltextnone-
item.fulltextNo Fulltext-
crisitem.author.deptFakultet tehničkih nauka, Departman za energetiku, elektroniku i telekomunikacije-
crisitem.author.deptInstitut BioSense-
crisitem.author.orcid0000-0003-2279-4545-
crisitem.author.parentorgFakultet tehničkih nauka-
crisitem.author.parentorgUniverzitet u Novom Sadu-
Appears in Collections:FTN Publikacije/Publications
Show simple item record

Page view(s)

23
Last Week
9
Last month
0
checked on May 3, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.