Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/8707
DC FieldValueLanguage
dc.contributor.authorŠtrbac, Brankoen
dc.contributor.authorJokic V.en
dc.date.accessioned2019-09-30T09:10:34Z-
dc.date.available2019-09-30T09:10:34Z-
dc.date.issued2013-09-01en
dc.identifier.issn11201797en
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/8707-
dc.description.abstractIntroduction: The aim of this study was to evaluate three-dimensional (3D) set-up errors and propose optimum margins for planning target volume (PTV) coverage in head and neck radiotherapy. Methods: Thirty-five patients were included in the study. The total number of portal images studied was 632. Population systematic (σ) and random (σ) errors for the patients with head and neck cancer were evaluated based on the portal images in the caudocranial longitudinal (CC) and left-right lateral (LR) direction measured in the anterior-posterior (AP) field, as well as from the images in the caudocranial longitudinal (CC) and dorsoventral lateral (DV) direction measured in the lateral (LAT) field. The values for the clinical-to-planning target volume (CTV-PTV) margins were calculated using ICRU Report 62 recommendations, along with Stroom's and van Herk's formulae. Results: The standard deviations of systematic set-up errors (σ) ranged from 1.51 to 1.93mm while the standard deviations of random set-up (σ) errors fell in between 1.77 and 1.86mm. The mean 3D vector length of displacement was 2.66mm. PTV margins calculated according to ICRU, Stroom's and van Herk's models were comprised between 1.95 and 6.16mm in the three acquisition directions. Discussion and conclusions: Based on our results we can conclude that a 6-mm extension of CTV to PTV margin, as the lower limit, is enough to ensure that 90% of the patients treated for head and neck cancer will receive a minimum cumulative CTV dose greater than or equal to 95% of the prescribed dose. © 2012 Associazione Italiana di Fisica Medica.en
dc.relation.ispartofPhysica Medicaen
dc.titleEvaluation of set-up errors in head and neck radiotherapy using electronic portalimagingen
dc.typeJournal/Magazine Articleen
dc.identifier.doi10.1016/j.ejmp.2012.12.001en
dc.identifier.pmid29en
dc.identifier.scopus2-s2.0-84881669871en
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/84881669871en
dc.relation.lastpage536en
dc.relation.firstpage531en
dc.relation.issue5en
dc.relation.volume29en
item.grantfulltextnone-
item.fulltextNo Fulltext-
crisitem.author.deptFakultet tehničkih nauka, Departman za proizvodno mašinstvo-
crisitem.author.parentorgFakultet tehničkih nauka-
Appears in Collections:FTN Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

17
checked on May 10, 2024

Page view(s)

21
Last Week
7
Last month
6
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.