Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке:
https://open.uns.ac.rs/handle/123456789/7010
Назив: | Laboratory monitoring of the haemostatic system changes during orthotopic liver transplantation | Аутори: | Slađana Novaković-Anučin Sanja Gnip Višnja Čanak Đurđina Jurišić Pavica Radović Svetlana Erdeljan Zoran Milošević Gorana Mitić |
Кључне речи: | liver transplantation;haemostatic system;Laboratory monitoring | Датум издавања: | 1-јан-2013 | Часопис: | Srpski Arhiv za Celokupno Lekarstvo | Сажетак: | Introduction In liver diseases, all components of the haemostatic system are changed and the degree of dysfunction is proportional to hepatocellular damage. During the liver transplantation, values of haemostatic parameters show substantial changes, while postoperatively there is a gradual normalisation of the haemostatic system function. Objective The aim was to monitor the changes of the haemostatic system intraoperatively and postoperatively, including the dynamics at which physiological values of parameters are reached after transplantation. Methods There were 17 cadaveric transplantations performed at the Clinical Centre of Vojvodina in the period from June 2008 to February 2012. The following parameters were tested: platelets, activated partial thromboplastin, prothrombin and thrombin time, fibrinogen, euglobulin clot lysis time, D-dimer, antithrombin and heparinemia. The results were presented intraoperatively in phases of transplantation, and postoperatively from day 1 to day 7, ending with postoperative day 14. Results During transplantation, the most pronounced disorders among those observed are: thrombocytopenia (96±66.1×10<sup>9</sup>/L), prolonged activated partial thromboplastin (1.80±0.8 R), prothrombin (1.59±0.4 R) and thrombin time (2.03±1.7 R), hypofibrinogenemia (2.13±0.5 g/L), hyperfibrinolysis (29±12.0 min), increase of D-dimer (1393±1220.4 ng/mL) and decrease of antithrombin (61±18.0%). Further monitoring after transplantation from postoperative day 1 revealed a gradual normalisation in the values, reaching physiological values for all parameters on postoperative day 14, except for the sustained high value of D-dimer (2606±1055.1 ng/mL). Heparinemia was within the prophylactic range (0.26±0 IU/mL). Conclusion Thorough monitoring of the haemostatic system parameters in liver transplantations is of great importance, as it enables the use of optimal substitution therapy during and after transplantation, as well as an adequate postoperative thromboprophylaxis. Our study has shown normalisation of investigated laboratory parameters within 7-14 days after transplantation. | URI: | https://open.uns.ac.rs/handle/123456789/7010 | ISSN: | 3708179 | DOI: | 10.2298/SARH1310608N |
Налази се у колекцијама: | MDF Publikacije/Publications |
Приказати целокупан запис ставки
SCOPUSTM
Навођења
5
проверено 10.05.2024.
Преглед/и станица
46
Протекла недеља
9
9
Протекли месец
0
0
проверено 10.05.2024.
Google ScholarTM
Проверите
Алт метрика
Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.