Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/562
DC FieldValueLanguage
dc.contributor.authorVranić, Ivanaen_US
dc.contributor.authorVranić, Ivonaen_US
dc.contributor.authorBoris Antićen_US
dc.contributor.authorGoran Stojanovićen_US
dc.contributor.authorAl-Salami, Hanien_US
dc.date.accessioned2019-09-23T10:08:59Z-
dc.date.available2019-09-23T10:08:59Z-
dc.date.issued2019-02-01-
dc.identifier.issn1335-8871en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/562-
dc.description.abstractAccurate measurement of electrocardiograms (ECG) is critical for effective diagnosis of patient's cardiac functions. Detailed examination of filters' effects on ECG accuracy, reproducibility and robustness covering a wide range of available commercial products can provide valuable information on the relationship between quality and effectiveness of filters, and assessments of patients' cardiac functions. In this study, ECG device with 12 leads and built-in filters used for ECG measurements was assessed on human volunteers. Results showed that with respect to measuring QRS wave duration and R-amplitude variation, there was a 4 % inaccuracy when the main filter was ON and OFF, and R-amplitude variation was most pronounced in the V4 lead. Accordingly, variability of R-amplitude and length of QRS wave can be reduced by the use of appropriate lead, and filter activation during the ECG assessment.en_US
dc.language.isoen_USen_US
dc.publisherSciendoen_US
dc.relationH2020 MEDLEMen_US
dc.relation.ispartofMeasurement Science Reviewen_US
dc.subjectElectrocardiogramen_US
dc.subjectfiltersen_US
dc.subjectQRS-amplitudeen_US
dc.subjectQRS-durationen_US
dc.titleInfluence of the main filter on QRS-amplitude and duration in human electrocardiogramen_US
dc.typeArticleen_US
dc.identifier.doi10.2478/msr-2019-0005-
dc.identifier.scopus2-s2.0-85062519552-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85062519552-
dc.description.versionPublisheden_US
dc.relation.lastpage34en_US
dc.relation.firstpage29en_US
dc.relation.issue1en_US
dc.relation.volume19en_US
item.fulltextWith Fulltext-
item.grantfulltextopen-
crisitem.author.deptFakultet tehničkih nauka, Departman za energetiku, elektroniku i telekomunikacije-
crisitem.author.deptFakultet tehničkih nauka, Departman za energetiku, elektroniku i telekomunikacije-
crisitem.author.orcid0000-0003-2098-189X-
crisitem.author.parentorgFakultet tehničkih nauka-
crisitem.author.parentorgFakultet tehničkih nauka-
Appears in Collections:FTN Publikacije/Publications
Files in This Item:
File SizeFormat
ECG2019.pdf1.05 MBAdobe PDFView/Open
Show simple item record

SCOPUSTM   
Citations

2
checked on May 3, 2024

Page view(s)

48
Last Week
6
Last month
2
checked on May 10, 2024

Download(s)

53
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.