Nаziv: Hydrodynamics of an external-loop airlift reactor with inserted membrane
Аutоri: Kojić, Predrag 
Popović, Svetlana 
Tokić, Milenko
Šijački, Ivana
Lukić, Nataša 
Jovičević, Dragica
Petrović, Dragan
Dаtum izdаvаnjа: 1-апр-2017
Čаsоpis: Brazilian Journal of Chemical Engineering
Sažetak: © 2018 Assoc. Brasiliera de Eng. Quimica / Braz. Soc. Chem. Eng..All Rights Reserved. The objective of this study was to investigate the hydrodynamics of an external-loop airlift membrane reactor (ELAMR). The ELAMR was operated in two modes: without (mode A) and with bubbles in the downcomer (mode B), depending on the liquid level in the gas separator. The influence of the gas distributor's geometry and various alcohol solutions on the hydrodynamics of the ELAMR was studied. Results for the gas holdup and the downcomer liquid velocity are commented with respect to an external-loop airlift reactor of the same geometry but without the membrane in the downcomer (ELAR). Due to the presence of the membrane in the downcomer, acting as the local hydrodynamic resistance, the gas holdup in the riser of the ELAMR increases maximally by 16%, while the liquid velocity in the downcomer decreases up to 50%. The values of the gas holdup and liquid velocity predicted by the application of empirical power law correlations and a feed forward back propagation neural network (ANN) are in very good agreement with experimental values.
URI: https://open.uns.ac.rs/handle/123456789/2391
ISSN: 01046632
DOI: 10.1590/0104-6632.20170342s20150399
Nаlаzi sе u kоlеkciјаmа:TF Publikacije/Publications

Prikаzаti cеlоkupаn zаpis stаvki

SCOPUSTM   
Nаvоđеnjа

12
prоvеrеnо 03.05.2024.

Prеglеd/i stаnicа

29
Prоtеklа nеdеljа
3
Prоtеkli mеsеc
0
prоvеrеnо 10.05.2024.

Google ScholarTM

Prоvеritе

Аlt mеtrikа


Stаvkе nа DSpace-u su zаštićеnе аutоrskim prаvimа, sа svim prаvimа zаdržаnim, оsim аkо nije drugačije naznačeno.