Please use this identifier to cite or link to this item:
https://open.uns.ac.rs/handle/123456789/203
DC Field | Value | Language |
---|---|---|
dc.contributor.author | Dragutinovic N. | en |
dc.contributor.author | Nakomčić-Smaragdakis, Branka | en |
dc.contributor.author | Djuric S. | en |
dc.contributor.author | Djordjic D. | en |
dc.date.accessioned | 2019-09-23T10:04:59Z | - |
dc.date.available | 2019-09-23T10:04:59Z | - |
dc.date.issued | 2019-07-01 | en |
dc.identifier.uri | https://open.uns.ac.rs/handle/123456789/203 | - |
dc.description.abstract | © 2019 Author(s). Crop residues could provide a local, sustainable, and low-cost solid fuel alternative to woody biomass for heat supply in the agricultural community. However, utilization of crop residues on a small scale is associated with increased pollutant emissions, as well as ash-related operational problems. There is ongoing research on fuel conditioning measures, such as fuel leaching, fuel blending, and using mineral additives, as a manner to mitigate these issues. The purpose of this study is to investigate the applicability of additives in the combustion of crop residues under everyday conditions. To this end, wheat straw pellets were combusted in a 30 kW boiler with and without additives (kaolinite and MgO, 2 wt. % and 4 wt. %). Carbon monoxide (CO) and particulate matter (PM) emissions have been monitored during combustion experiments, as well as changes in bottom ash behavior and composition. The results have shown that additives slightly decrease the heating value of the fuel (3%-6%). During experiments with additized wheat straw pellets, higher emissions of CO were observed. Combustion of pure not additized wheat straw pellets resulted in a PM emission of 568 mg/Nm3, which decreased with additives. Both researched additives increase the four characteristic ash deformation temperatures. | en |
dc.relation.ispartof | Journal of Renewable and Sustainable Energy | en |
dc.title | Investigation of additives in combustion of wheat straw pellets in a small scale boiler | en |
dc.type | Journal/Magazine Article | en |
dc.identifier.doi | 10.1063/1.5088640 | en |
dc.identifier.scopus | 2-s2.0-85068761226 | en |
dc.identifier.url | https://api.elsevier.com/content/abstract/scopus_id/85068761226 | en |
dc.relation.issue | 4 | en |
dc.relation.volume | 11 | en |
item.grantfulltext | none | - |
item.fulltext | No Fulltext | - |
crisitem.author.dept | Fakultet tehničkih nauka, Departman za inženjerstvo zaštite životne sredine i zaštite na radu | - |
crisitem.author.parentorg | Fakultet tehničkih nauka | - |
Appears in Collections: | FTN Publikacije/Publications |
SCOPUSTM
Citations
6
checked on Sep 9, 2023
Page view(s)
31
Last Week
7
7
Last month
8
8
checked on May 10, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.