Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/19196
Title: Evaluation of different LSC methods for <sup>222</sup>Rn determination in waters
Authors: Nikolov Jovana 
Stojković Ivana 
Todorović Nataša 
Tenjović Branislava
Vuković Srđan
Knežević Jovana 
Issue Date: 2018
Journal: Applied Radiation and Isotopes
Abstract: © 2018 Elsevier Ltd Monitoring of 222Rn in drinking or surface waters, as well as in groundwater has been performed regularly in connection with geological, hydrogeological and hydrological surveys and health hazard studies. Liquid scintillation counting (LSC) is often preferred analytical method for 222Rn measurements in waters as it allows multiple-sample automatic analysis. LSC method implies mixing of water samples with organic scintillation cocktail, which triggers radon diffusion from the aqueous into an organic phase for which it has a much greater affinity, eliminating the possibility of radon emanation in that manner. The main aim of this paper is calibration of the liquid scintillation counter Qunatulus 1220™ for measuring of radon in water and evaluation of two different methods (one-phase and two-phase) in order to obtain the most suitable LSC technique for radon in water measurement. In this study four different scintillation cocktails were tested: one miscible (Ultima Gold AB) and three immiscible (High Efficiency Mineral Oil Scintillator, Opti-Fluor O and Ultima Gold F). Evaluation of presented methods was based on obtained detection efficiency and achieved Minimal Detectable Activity (MDA) values. Comparison of presented methods, accuracy and precision, as well as different scintillation cocktail's performance, was considered from results of measurements of 226Ra spiked water samples with known activity and environmental samples. LSC results were compared with the results of radon in water measurement obtained by alpha spectrometer RAD7. Calibration was done as a dependence of calibration factor (CF) from Pulse Shape Analysis (PSA). According to the obtained results, with proper adjustment of calibration parameters, both methods could be used for radon in water measurements. The obtained MDA values for all four scintillation cocktails are very low, less than 0.1 Bq l−1 for measuring time of 300 min.
URI: https://open.uns.ac.rs/handle/123456789/19196
ISSN: 0969-8043
DOI: 10.1016/j.apradiso.2018.09.013
Appears in Collections:PMF Publikacije/Publications

Show full item record

SCOPUSTM   
Citations

7
checked on May 10, 2024

Page view(s)

40
Last Week
5
Last month
4
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.