Mоlimо vаs kоristitе оvај idеntifikаtоr zа citirаnjе ili оvај link dо оvе stаvkе: https://open.uns.ac.rs/handle/123456789/19178
Nаziv: New sample preparation method based on task-specific ionic liquids for extraction and determination of copper in urine and wastewater
Аutоri: Trtić-Petrović Tatjana
Aleksandra Dimitrijevic
Nikola Zdolšek
Đorđević Jelena
Aleksandar Tot 
Vraneš Milan 
Gadžurić Slobodan 
Dаtum izdаvаnjа: 2018
Čаsоpis: Analytical and Bioanalytical Chemistry
Sažetak: © 2017, Springer-Verlag GmbH Germany. In this study, four hydrophilic ionic liquids (ILs) containing 1-alkyl-3-methylimidazolim cation and either salicylate or chloride anions were synthetized and studied as new task-specific ionic liquids (TSILs) suitable for aqueous biphasic system (ABS) formation and selective one-step extraction of copper(II). TSILs are designed so that the anion is responsible for forming the complex with metal(II) and preventing hydrolysis of metal cations at very strong alkaline pH, whereas the cation is responsible for selective extraction of metal(II)-salicylate complexes. It was found that 1-butyl-3-methylimidazolium salicylate could be used for selective extraction of Cu(II) in the presence of Zn(II), Cd(II), and Pb(II) at very alkaline solution without metal hydroxide formation. It was assumed that formation of metal(II)–salicylate complexes prevents the hydrolysis of the metal ions in alkaline solutions. The determined stability constants for Cu(II)–salicylate complexes, where salicylate was derived from different ionic liquids, indicated that there was no significant influence of the cation of the ionic liquid on the stability of the complexes. The ABS based on 1-butyl-3-methylimidazolium salicylate has been applied as the sample preparation step prior to voltammetric determination of Cu(II). The effect of volume of aqueous sample and IL and extraction time were investigated and optimum extraction conditions were determined. The obtained detection limits were 8 ng dm−3. The optimized method was applied for the determination of Cu(II) in tap water, wastewater, and urine. The study indicated that application of the ABS based on 1-butyl-3-methylimidazolium salicylate ionic liquid could be successfully applied as the sample preparation method for the determination of Cu(II) from various environmental samples. [Figure not available: see fulltext.].
URI: https://open.uns.ac.rs/handle/123456789/19178
ISSN: 1618-2642
DOI: 10.1007/s00216-017-0705-z
Nаlаzi sе u kоlеkciјаmа:PMF Publikacije/Publications

Prikаzаti cеlоkupаn zаpis stаvki

SCOPUSTM   
Nаvоđеnjа

18
prоvеrеnо 03.05.2024.

Prеglеd/i stаnicа

22
Prоtеklа nеdеljа
8
Prоtеkli mеsеc
0
prоvеrеnо 10.05.2024.

Google ScholarTM

Prоvеritе

Аlt mеtrikа


Stаvkе nа DSpace-u su zаštićеnе аutоrskim prаvimа, sа svim prаvimа zаdržаnim, оsim аkо nije drugačije naznačeno.