Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/16686
Назив: Trace level voltammetric determination of lead and cadmium in sediment pore water by a bismuth-oxychloride particle-multiwalled carbon nanotube composite modified glassy carbon electrode
Аутори: Cerovac Sandra
Guzsvány Valéria
Kónya Zoltan
Ashrafi M.Amir
Švancara Ivan
Rončević Srđan 
Akos Kukovecz
Dalmacija Božo 
Vytřas Karel
Датум издавања: 2015
Часопис: Talanta
Сажетак: © 2014 Elsevier B.V. All rights reserved. Two multiwalled carbon nanotubes-based composites modified with bismuth and bismuth-oxychloride particles were synthesized and attached to the glassy carbon electrode substrate. The resultant configurations, Bi/MWCNT-GCE and BiOCl/MWNT-GCE, were then characterized with respect to their physicochemical properties and electroanalytical performance in combination with square-wave anodic stripping voltammetry (SWASV). Further, some key experimental conditions and instrumental parameters were optimized; namely: the supporting electrolyte composition, accumulation potential and time, together with the parameters of the SWV-ramp. The respective method with both electrode configurations has then been examined for the trace level determination of Pb2+ and Cd2+ ions and the results compared to those obtained with classical bismuth-film modified GCE. The different intensities of analytical signals obtained at the three electrodes for Pb2+ and Cd2+ vs. the saturated calomel reference electrode had indicated that the nature of the modifiers and the choice of the supporting electrolyte influenced significantly the corresponding stripping signals. The most promising procedure involved the BiOCl/MWCNT-GCE and the acetate buffer (pH 4.0) offering limits of determination of 4.0 μg L-1 Cd2+ and 1.9 μg L-1 Pb2+ when accumulating for 120 s at a potential of -1.20 V vs. ref. The BiOCl/MWCNT electrode was tested for the determination of target ions in the pore water of a selected sediment sample and the results agreed well with those obtained by graphite furnace atomic absorption spectrometry.
URI: https://open.uns.ac.rs/handle/123456789/16686
ISSN: 0039-9140
DOI: 10.1016/j.talanta.2014.12.002
Налази се у колекцијама:PMF Publikacije/Publications

Приказати целокупан запис ставки

SCOPUSTM   
Навођења

98
проверено 20.05.2023.

Преглед/и станица

7
Протекла недеља
1
Протекли месец
0
проверено 10.05.2024.

Google ScholarTM

Проверите

Алт метрика


Ставке на DSpace-у су заштићене ауторским правима, са свим правима задржаним, осим ако није другачије назначено.