Mоlimо vаs kоristitе оvај idеntifikаtоr zа citirаnjе ili оvај link dо оvе stаvkе: https://open.uns.ac.rs/handle/123456789/16436
Nаziv: Trace level voltammetric determination of Zn(II) in selected nutrition related samples by bismuth-oxychloride-multiwalled carbon nanotube composite based electrode
Аutоri: Petrović Sandra
Guzsvány Valéria
Nikola Ranković
Beljin Jelena 
Rončević Srđan 
Dalmacija Božo 
Ashrafi M.Amir
Kónya Zoltan
Švancara Ivan
Vytřas Karel
Dаtum izdаvаnjа: 2019
Čаsоpis: Microchemical Journal
Sažetak: © 2018 Elsevier B.V. Bismuth-oxychloride-multiwalled carbon nanotube composite material was applied as surface modifier of glassy carbon electrode (BiOCl-MWCNT/GCE) for rapid and reliable trace level determination of Zn(II) in selected foodstuffs. The method development encompasses the optimization of electrode preparation including the transmission electron microscopic study of the modifier suspension, selection of the supporting electrolyte pH, the adjustment of the operation parameters of the SW-ASV measurements and the investigation of matrix effects. By the BiOCl-MWCNT/GCE recorded calibration curve showed an excellent linearity towards Zn reoxidation peak intensity in the concentration range from 2.50 to 80.0 μg L−1 with the calculated LOD of 0.75 μg L−1 which was associated with 120 s accumulation time and accumulation potential −1.40 V vs SCE in acetate buffer pH 4.5. A satisfactory repeatability expressed as relative standard deviation of 4.8% was obtained in the case of 10.0 μg L−1 Zn(II) in model solution. The Zn(II) reoxidation signal from BiOCl-MWCNT/GCE received by the optimized SW-ASV method was compared with those recorded with bare, classical bismuth-film, multiwalled carbon nanotubes and by in situ made advanced bismuth-film-MWCNTs working electrodes. The applicability of the proposed BiOCl-MWCNT/GCE based method was corroborated via measuring the target analyte in two nutrition related real samples: in a dietary supplement and in a brewer's yeast sample. Comparative flame atomic absorption spectrometric measurements verified the obtained results in the case of yeast sample.
URI: https://open.uns.ac.rs/handle/123456789/16436
ISSN: 0026-265X
DOI: 10.1016/j.microc.2018.12.053
Nаlаzi sе u kоlеkciјаmа:PMF Publikacije/Publications

Prikаzаti cеlоkupаn zаpis stаvki

SCOPUSTM   
Nаvоđеnjа

17
prоvеrеnо 20.11.2023.

Prеglеd/i stаnicа

22
Prоtеklа nеdеljа
1
Prоtеkli mеsеc
0
prоvеrеnо 10.05.2024.

Google ScholarTM

Prоvеritе

Аlt mеtrikа


Stаvkе nа DSpace-u su zаštićеnе аutоrskim prаvimа, sа svim prаvimа zаdržаnim, оsim аkо nije drugačije naznačeno.