Назив: | Use of multiple storage elements to improve the second law efficiency of a thermal energy storage system. Part II: Completion of the analysis and presentation of results | Аутори: | Sekulic D. Krane R. |
Датум издавања: | 1-јан-1992 | Часопис: | ECOS '92 International Symposium | Сажетак: | This work investigates the use of multiple storage units connected in series to improve the thermodynamic efficiency of a sensible heat thermal energy storage system. The study is focused on two-element systems which are shown to have entropy generation numbers up to 38% smaller than those of the corresponding single-storage-element systems. Thus, the use of only two storage elements in series can provide rather dramatic increases in the thermodynamic efficiency of a thermal energy storage system. Also, the heat exchanger sizes (NTU's) predicted for the two-element systems are shown to be small enough to be practical. | URI: | https://open.uns.ac.rs/handle/123456789/14843 | ISBN: | 0791806316 |