Молимо вас користите овај идентификатор за цитирање или овај линк до ове ставке: https://open.uns.ac.rs/handle/123456789/14632
Назив: Effect of insulation construction bending on stator winding failure
Аутори: Vereb, Laslo
Osmokrović P.
Vujisić M.
Lazarević Z.
Kartalović N.
Датум издавања: 1-окт-2007
Часопис: IEEE Transactions on Dielectrics and Electrical Insulation
Сажетак: This paper investigates electrical breakdown of interconduetor insulation, which presents an obstacle to the increase of the rated voltage of electrical machines as a means to improve efficiency of electrical energy exploitation. We have investigated a large number of samples searching for weak points in interconduetor insulation along the coil of a high voltage asynchronous machine. The experiments were performed on lacquer-glass-glass-lacquer conductor insulation. Location of weak points and breakdown voltage levels have been determined. © 2007 IEEE.
URI: https://open.uns.ac.rs/handle/123456789/14632
ISSN: 10709878
DOI: 10.1109/TDEI.2007.4339493
Налази се у колекцијама:Naučne i umetničke publikacije