Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/12508
Title: Rapid, trace-level direct cathodic voltammetric determination of dopamine by oxidized multiwalled carbon nanotube–modified carbon paste electrode in selected samples of pharmaceutical importance
Authors: Jasmina Anojčić
Valerija (Valéria) Guzvanj (Guzsvány) 
Zoltan Kónya
Momir Mikov 
Keywords: Dopamine;Oxidized multiwalled carbon nanotubes;Injection/infusion samples;Electrochemical sensor;Square wave voltammetry;Carbon paste electrode
Issue Date: 1-Dec-2019
Journal: Ionics
Abstract: © 2019, Springer-Verlag GmbH Germany, part of Springer Nature. Selected carbonaceous nanomaterial–modified carbon paste electrodes (CPEs) were compared for trace-level determination of dopamine (DA) by direct cathodic square wave voltammetry (SWV). The advanced nanomaterials containing electrodes were obtained from homemade multiwalled carbon nanotubes (MWCNTs) in their native and functionalized (ox-MWCNTs) forms, commercially available MWCNTs, single-walled carbon nanotubes, and fullerene, by a very simple drop coating method, and from classical CPE which consists of graphite powder and paraffin oil only. The comparative SWV measurements confirmed the priority of ox-MWCNT/CPE as it exhibited the best analytical performance with a well-shaped and intensive DA signal, which strongly depended upon pH and exhibited the most favorable characteristics at pH 6.3 (0.1 M phosphate buffer solution). The cyclic voltammetric (CV) characterization of DA on ox-MWCNT/CPE confirmed the reversible process and much higher sensitivity of this electrode in comparison with the other ones. Fourier transform infrared (FTIR) and Raman spectroscopic measurements indicated a significant difference between MWCNTs and ox-MWCNTs, which is the consequence of the chemical oxidation/functionalization of the latter one having a positive influence on its sensing properties. The optimized SWV method was characterized by a linear concentration range of 16.15–192.70 ng mL−1 DA, a relative standard deviation (RSD) lower than 1.3%, and a detection limit in the model solution of 4.89 ng mL−1. Also, interferences from ascorbic acid were negligible. The developed method was successfully applied for DA determination in injection/selected infusion matrix solutions, whereby the obtained results were in good agreement with DA content declared by the producer with RSD of the method below 1.0%.
URI: https://open.uns.ac.rs/handle/123456789/12508
ISSN: 09477047
DOI: 10.1007/s11581-019-03156-5
Appears in Collections:PMF Publikacije/Publications

Show full item record

SCOPUSTM   
Citations

10
checked on Aug 12, 2023

Page view(s)

29
Last Week
15
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.