Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/9592
Title: Fast timed active shield for a gamma-ray spectrometer
Authors: Todorović, Nenad
Mrđa, Dušan 
Bikit I.
Forkapić, Sofija 
Slivka, Jaroslav
Vesković, Miroslav 
Issue Date: 1-Dec-2008
Journal: Astroparticle, Particle and Space Physics, Detectors and Medical Physics Applications - Proceedings of the 10th Conference
Abstract: The operational problems of the gamma ray spectrometer shielded passively with 12 cm of lead and actively by five 0.5 m x 0.5 m x 0.05 m plastic veto shields are described. In the present paper we describe the new results of our ground based actively shielded extended range low level gamma spectrometer emphasizing the anticoincidence timing details which are unavoidable for the proper operation of the system After the new adjustment of active shield germanium system, total count rate in anticoincidence background spectrum was 0.38 c/s (50 keV-2 MeV), the achieved reduction factor with respect to the passively shield background spectrum is 2.42. The 51 1 keV reduction factor is 4.25.
URI: https://open.uns.ac.rs/handle/123456789/9592
ISBN: 9812819088
Appears in Collections:PMF Publikacije/Publications

Show full item record

Page view(s)

19
Last Week
0
Last month
0
checked on Mar 15, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.