Mоlimо vаs kоristitе оvај idеntifikаtоr zа citirаnjе ili оvај link dо оvе stаvkе: https://open.uns.ac.rs/handle/123456789/7430
Pоljе DC-аVrеdnоstЈеzik
dc.contributor.authorBaloš, Sebastianen_US
dc.contributor.authorSiđanin, Leposavaen_US
dc.contributor.authorPilić, Brankaen_US
dc.date.accessioned2019-09-30T09:01:56Z-
dc.date.available2019-09-30T09:01:56Z-
dc.date.issued2014-
dc.identifier.issn17858860en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/7430-
dc.description.abstract© 2014, Budapest Tech Polytechnical Institution, All rights reserved. Various hardness test methods have been used to determine the polymer materials resistance to local plastic deformation in scientific community. The most commonly used method is Vickers microindentation. However, it is of crucial importance to fully understand the influence of the indentation load, since its value influences the obtained result. In this paper, two commercial PMMA dental reline resins in untreated and microwave treated condition have been tested. Vickers microindentation with different loads has been used to assess the materials microhardness: 30, 50, 70, 200, 300 and 500 gf. One way ANOVA statistical analysis followed by Tukey’s test was used to determine the statistical differences between various groups. Finally, three models that quantitatively describe load-dependence of the measured Vickers hardness values were used: Meyer’s law, PSR and modified PSR model. It was found that the optimal load for determining PMMA dental reline resins in both untreated and microwave treated conditions is 300 gf. This value may be regarded as loading independent hardness, or HLIH. At lower loads, a more or less pronounced indentation size effect was noticed, while at higher loads, forked crack development leads to an unreliable indentation diagonal measurement and therefore an unreliable microhardness result. The most adequate load-dependence model was found to be modified PSR, that takes into consideration the surface stresses induced by specimen preparation by grinding.en_US
dc.language.isoenen_US
dc.relation.ispartofActa Polytechnica Hungaricaen_US
dc.titleIndentation size effect in autopolymerized and microwave post treated poly(methyl methacrylate) denture reline resinsen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.12700/aph.11.07.2014.07.15-
dc.identifier.scopus2-s2.0-84907250274-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/84907250274-
dc.description.versionPublisheden_US
dc.relation.lastpage249en_US
dc.relation.firstpage239en_US
dc.relation.issue7en_US
dc.relation.volume11en_US
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.deptDepartman za proizvodno mašinstvo-
crisitem.author.deptKatedra za inženjerstvo materijala-
crisitem.author.parentorgFakultet tehničkih nauka-
crisitem.author.parentorgTehnološki fakultet-
Nаlаzi sе u kоlеkciјаmа:TF Publikacije/Publications
Prikаzаti јеdnоstаvаn zаpis stаvki

SCOPUSTM   
Nаvоđеnjа

4
prоvеrеnо 03.05.2024.

Prеglеd/i stаnicа

35
Prоtеklа nеdеljа
15
Prоtеkli mеsеc
0
prоvеrеnо 10.05.2024.

Google ScholarTM

Prоvеritе

Аlt mеtrikа


Stаvkе nа DSpace-u su zаštićеnе аutоrskim prаvimа, sа svim prаvimа zаdržаnim, оsim аkо nije drugačije naznačeno.