Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/6150
DC FieldValueLanguage
dc.contributor.authorBrycht M.en
dc.contributor.authorBurnat B.en
dc.contributor.authorSkrzypek S.en
dc.contributor.authorGuzvanj (Guzsvány), Valerija (Valéria)en
dc.contributor.authorGutowska N.en
dc.contributor.authorRobak J.en
dc.contributor.authorNosal-Wiercińska A.en
dc.date.accessioned2019-09-30T08:53:00Z-
dc.date.available2019-09-30T08:53:00Z-
dc.date.issued2015-03-10en
dc.identifier.issn00134686en
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/6150-
dc.description.abstract© 2015 Elsevier Ltd All rights reserved. A new, simple, rapid, and inexpensive voltammetric method for the determination of a novel fungicide, fludioxonil (Flu), was firstly developed using square wave voltammetry (SWV). This was based on its electrochemical cathodic reduction at about -1.1 V vs. an Ag/AgCl/KCl reference electrode in citrate-phosphate (C-P) buffer (pH 3.7) on a renewable silver amalgam film electrode (Hg(Ag)FE). To select the optimum experimental conditions, the effect of the supporting electrolyte, pH, conditioning potential and conditioning time, frequency, amplitude, step potential, and equilibration time were studied. Under optimized conditions, the proposed method exhibited acceptable analytical performances in terms of linearity (over a concentration range from 2.00 × 10-6 to 2.25 × 10-5 mol L-1), the detection limit (LOD = 5.81 × 10-7 mol L-1) and the quantification limit (LOQ = 1.94 × 10-6 mol L-1) for a solution containing Flu. The validation of the method was carried out. The developed procedure was successfully applied to determine Flu in the spiked Warta River water samples. To understand the Flu electrode mechanism, the cyclic voltammetry (CV) technique was applied. The reduction mechanism was also confirmed using mass spectrometry with the electrospray ionization (ESI-MS) technique. The influence of Flu on the corrosion properties of stainless steels used to produce agricultural tools were investigated using electrochemical techniques.en
dc.relation.ispartofElectrochimica Actaen
dc.titleVoltammetric and corrosion studies of the fungicide fludioxonilen
dc.typeJournal/Magazine Articleen
dc.identifier.doi10.1016/j.electacta.2015.01.130en
dc.identifier.scopus2-s2.0-84922442225en
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/84922442225en
dc.relation.lastpage297en
dc.relation.firstpage287en
dc.relation.volume158en
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.deptPrirodno-matematički fakultet, Departman za hemiju, biohemiju i zaštitu životne sredine-
crisitem.author.parentorgPrirodno-matematički fakultet-
Appears in Collections:PMF Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

15
checked on May 10, 2024

Page view(s)

14
Last Week
2
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.