dc.description.abstractThis paper investigates and analyzes a typical multi-zone office building's annual energy performance for the location and climate data of central Belgrade. The aim is to evaluate the heating, ventilation and air conditioning system's and heat recovery unit's performance in order to conduct the most preferable heating and cooling solution for the typical climate of Belgrade city. The energy performance of four heating, ventilation and air conditioning system types (heat pump - air to air, gas-electricity, electrical and fan coil system) was analyzed, compared and evaluated on a virtual office building model in order to assess the total annual energy performance and to determine the efficiency of the heat recovery unit's application. Further, the parameters of an energy efficient building envelope, heating, ventilation and air conditioning system, internal loads, building operation schedules and occupancy intervals were implemented into the multi-zone analysis model. The investigation was conducted in EnergyPlus simulation engine using system thermodynamic algorithms and surface/air heat balance modules. The comparison and evaluation of the obtained results was achieved through the conversion of the calculated total energy demand into primary energy. The goal is conduct the most preferable heating and cooling solution (best case scenario) for the climate of Belgrade city and outline major criteria in qualitative enhancement.en
dc.relation.ispartofThermal Scienceen
dc.titleEnergy performance modelling and heat recovery unit efficiency assessment of an office buildingen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.2298/TSCI140311102H-
dc.identifier.scopus2-s2.0-84979902239-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/84979902239-
dc.description.versionUnknownen_US
dc.relation.lastpage880en
dc.relation.firstpage865en
dc.relation.issue3en
dc.relation.volume19en
item.grantfulltextnone-
item.fulltextNo Fulltext-
Appears in Collections:Naučne i umetničke publikacije
Show simple item record

SCOPUSTM   
Citations

16
checked on Aug 12, 2023

Page view(s)

10
Last Week
9
Last month
0
checked on May 3, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.