Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/5291
DC FieldValueLanguage
dc.contributor.authorLepić T.en_US
dc.contributor.authorVeljančić D.en_US
dc.contributor.authorJovanikić O.en_US
dc.contributor.authorLepić M.en_US
dc.contributor.authorPetar Slankamenacen_US
dc.contributor.authorRaičević R.en_US
dc.date.accessioned2019-09-30T08:47:02Z-
dc.date.available2019-09-30T08:47:02Z-
dc.date.issued2015-12-01-
dc.identifier.issn428450en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/5291-
dc.description.abstract© 2015, Institut za Vojnomedicinske Naucne Informacije/Documentaciju. All rights reserved. Background/Aim. Transcranial color-coded duplex (TCCD) sonography allows visualization of the vessels being examined and measurement of the angle of insonation. The published literature suggests that blood vessels are insonated at the angle lower than 30 degrees, hence no correction for the angle is necessary. The aim of this study was to determine the availability of intracranial blood vessels for insonation, and the percentage of arteries and their segments which can be insonated at the angles lower than 30 degrees. Methods. The study included 120 patients (mean age 51). For each of the segments the angle of insonation was registered based on TCCD vizualization, and hemodynamic parameters were measured. The angle of insonation was measured using combined B-mode and color Doppler vizualization, as the angle between the direction of the ultrasound beam and the axis of the shown arterial segment. Results. The total success rate of insonation was 86.33% (1,554 out of 1,800). The mean angle of insonation value in all the examined arterial segments was 42 degrees. The insonation angle was higher than 30 degrees in about three quarters of the examined segments, especially in the A2 segment of the anterior cerebral artery (98%), the P1 segmet of the posterior cerebral artery (87%) and in the terminal internal carotid artery (83%). The A1 segment of the anterior cerebral artery showed the best insonation conditions with the angle of insonation lower than 30 degrees in 53% of the cases. Conclusion. The presented results of angles of insonation measurements for the anterior, middle and posterior cerebral arteries and their segments, as well as the terminal portion of the internal carotid artery clearly indicate that their average values in tested segments were very often higher than 30 degrees, which can cause an error in blood flow velocity measurement that cannot be ignored. The results confirm the necessity of correcting flow velocity values on the basis of the angle of insonation in TCCD sonography.en_US
dc.language.isoenen_US
dc.relation.ispartofVojnosanitetski Pregleden_US
dc.subjectultrasonography, doppler, transcranialen_US
dc.subjectultrasonography, doppler, duplexen_US
dc.subjectblood flow velocityen_US
dc.subjectcarotid artery, internalen_US
dc.subjectanterior cerebral arteryen_US
dc.subjectmiddle cerebral arteryen_US
dc.titleImportance of angle correction in transcranial color-coded duplex insonation of arteries at the base of the brainen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.2298/VSP141105009L-
dc.identifier.pmid72-
dc.identifier.scopus2-s2.0-84951764169-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/84951764169-
dc.description.versionPublisheden_US
dc.relation.lastpage1097en_US
dc.relation.firstpage1093en_US
dc.relation.issue12en_US
dc.relation.volume72en_US
item.fulltextNo Fulltext-
item.grantfulltextnone-
Appears in Collections:MDF Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

4
checked on May 10, 2024

Page view(s)

21
Last Week
1
Last month
2
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.