Please use this identifier to cite or link to this item:
https://open.uns.ac.rs/handle/123456789/515
Title: | Amperometric Determination of Glucose in White Grape and in Tablets as Ingredient by Screen-Printed Electrode Modified with Glucose Oxidase and Composite of Platinum and Multiwalled Carbon Nanotubes | Authors: | Guzvanj (Guzsvány), Valerija (Valéria) Anojčić J. Vajdle O. Radulović E. Madarász D. Kónya Z. Kalcher K. |
Issue Date: | 15-Feb-2019 | Journal: | Food Analytical Methods | Abstract: | © 2018, Springer Science+Business Media, LLC, part of Springer Nature. Multiwalled carbon nanotubes (MWCNTs) and nanocomposite made from MWCNTs and Pt nanoparticles (Pt-MWCNTs) were used as bulk modifiers of screen-printed carbon electrodes (SPCEs). Cyclic voltammetric and amperometric measurements were performed by the homemade substrate electrodes, the bare SPCE and the modified ones (MWCNT-SPCE and Pt-MWCNT-SPCE), with aim to investigate their applicability for determination of H2O2 in phosphate buffer solution (0.1 M; pH 7.50) as supporting electrolyte. Pt-MWCNT-SPCE showed improved analytical performances including the significant decrease in overpotential of H2O2 compared to SPCE and MWCNT-SPCE. So, Pt-MWCNT-SPCE served as substrate electrode for design of a simple first-generation biosensor made from glucose oxidase (GOx) and Nafion® forming the GOx/Pt-MWCNT-SPCE for reliable determination of glucose via its enzymatic by-product, the H2O2. The surface morphology characterization by scanning electron microscopy confirmed the presence of immobilized spherical shaped biosensing units at the GOx/Pt-MWCNT-SPCE. In the case of amperometry of glucose, optimal potential for the working electrode was − 0.50 V vs. SCE, and a satisfactory linearity was obtained in the tested concentration range from 65.8 to 260.6 μg mL−1, with estimated LOQ of 35.0 μg mL−1. The developed cost-effective amperometric method in combination with GOx/Pt-MWCNT-SPCE was successfully applied for the determination of glucose in selected food samples: white grapes and glucose tablets. The obtained results were in good agreement with those received by the alternatively used commercially available glucometer and by the producer declared value in the case of the tablet sample as well. | URI: | https://open.uns.ac.rs/handle/123456789/515 | ISSN: | 19369751 | DOI: | 10.1007/s12161-018-1387-7 |
Appears in Collections: | PMF Publikacije/Publications |
Show full item record
SCOPUSTM
Citations
12
checked on May 3, 2024
Page view(s)
29
Last Week
12
12
Last month
0
0
checked on May 10, 2024
Google ScholarTM
Check
Altmetric
Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.