Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/4132
DC FieldValueLanguage
dc.contributor.authorKrmar, Miodragen
dc.contributor.authorShtykov A.en
dc.contributor.authorGanezer K.en
dc.contributor.authorma G.en
dc.date.accessioned2019-09-23T10:32:10Z-
dc.date.available2019-09-23T10:32:10Z-
dc.date.issued2007-01-01en
dc.identifier.issn00942405en
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/4132-
dc.description.abstractSmall changes in the peak voltage of a diagnostic x‐ray tube can cause significant modifications in the absorbed dose or degrade the contrast of an x‐ray image. It has been suggested that kVp should be monitored routinely however a standardized noninvasive technique for kVp monitoring has yet to be developed. A number of x‐ray beam‐related quantities depend upon the endpoint energy including, intensity, penetrability and dosage. However, none of these parameters can be used to determine kVp for x‐ray tubes in general. If a material is irradiated by an x‐ray beam, spectra for Compton scattered photons as well as x‐ray fluorescence lines that are a characteristic of the target material can be simultaneously collected. The ratio of the integral number of Compton scattered photons and the number of fluorescent x‐ray photons is a function of the maximal beam energy and same time independent of the tube current, measurement geometry, and other quantities that are related to the experimental setup. CdTe detectors having sufficient energy resolution to distinguish individual x‐ray fluorescence lines and high efficiency for energies in the 10‐keV region were used in our measurements. Several materials covering a wide range of atomic numbers from Copper (Z=12) to lead (Z=82) were used as the medium for fluorescence and for scattering. A variety of scattering angles and detection geometries were tested. Our measurements have demonstrated that the ratio of the integral number of Compton scattered photons to that of fluorescent photons using a fixed geometry is a sensitive index of kVp (peak tube voltage). © 2007, American Association of Physicists in Medicine. All rights reserved.en
dc.relation.ispartofMedical Physicsen
dc.titleSU‐FF‐I‐53: X‐Ray Scattering and Fluorescence Spectroscopy as a Possible Tool for KVp Monitoringen
dc.typeJournal/Magazine Articleen
dc.identifier.doi10.1118/1.2760430en
dc.identifier.scopus2-s2.0-85024796419en
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85024796419en
dc.relation.firstpage2350en
dc.relation.issue6en
dc.relation.volume34en
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.deptPrirodno-matematički fakultet, Departman za fiziku-
crisitem.author.orcid0000-0002-0337-2411-
crisitem.author.parentorgPrirodno-matematički fakultet-
Appears in Collections:PMF Publikacije/Publications
Show simple item record

Page view(s)

22
Last Week
1
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.