Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/3713
DC FieldValueLanguage
dc.contributor.authorFerenc Vickoen_US
dc.contributor.authorZoran Radovanovićen_US
dc.contributor.authorTatjana Ivković Kapiclen_US
dc.contributor.authorDragana Đilasen_US
dc.contributor.authorDejan Lukićen_US
dc.contributor.authorMilanka Tatićen_US
dc.contributor.authorTatjana Petrovićen_US
dc.date.accessioned2019-09-23T10:29:32Z-
dc.date.available2019-09-23T10:29:32Z-
dc.date.issued2017-01-01-
dc.identifier.issn3708179en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/3713-
dc.description.abstract© 2017, Serbia Medical Society. All rights reserved. Introduction/Objective About a third of the breast lesions on mammography are clinically occult. The goals of surgical treatment are to locate, remove, and verify their presence in the removed breast tissue. Standard specimen mammography (SSM) has been an official procedure for the latter, while intraoperative digital specimen radiography (IDSR) was introduced recently. The aim of this study was to evaluate the use of IDSR versus SSM and possible benefits regarding the duration of the procedures (operating room occupancy), availability of digital mammography for additional number of patients, surgeon productivity, and the quality of performed services. Methods A retrospective chart review of 109 patients who underwent IDSR for nonpalpable breast lesions was performed between January 2014 and June 2016. We compared the difference in the duration of IDSR versus SSM procedure. We also observed the number of re-excisions and evaluated time-saving in the operating room workflow. Results The average duration of surgery in the IDSR group of patients was 51 minutes, compared to 64 minutes in the SSM group. Every IDSR procedure saved 13 minutes over the standard SSM. That would allow another 28 procedures in the same time frame, with the same quality of service compared with SSM. In that way we increased productivity by 27.5%. Additional operation/surgery was needed for histologically involved surgical margins in three cases (2.75%). Conclusion The use of new technology resulted in the rationalization of the operative room workflow and gave better productivity. More savings were obtained through the increase of digital mammography capacity for diagnostics, decrease of anesthesia duration, and better management of human resources. The number of “true” re-excisions, involving additional surgery, remained similar after introducing IDSR.en_US
dc.language.isoenen_US
dc.relation.ispartofSrpski Arhiv za Celokupno Lekarstvoen_US
dc.subjectnonpalpable breast tumorsen_US
dc.subjectspecimen radiographyen_US
dc.subjectnonpalpable lesion localizationen_US
dc.titleIntraoperative digital specimen radiography in the treatment of nonpalpable breast lesionsen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.2298/SARH161215071V-
dc.identifier.scopus2-s2.0-85033771480-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85033771480-
dc.description.versionPublisheden_US
dc.relation.lastpage381en_US
dc.relation.firstpage378en_US
dc.relation.issue7-8en_US
dc.relation.volume145en_US
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.deptKatedra za hirurgiju-
crisitem.author.deptKatedra za onkologiju-
crisitem.author.deptKatedra za patologiju-
crisitem.author.deptKatedra za anesteziju i perioperativnu medicinu-
crisitem.author.orcid0000-0003-4249-9260-
crisitem.author.parentorgMedicinski fakultet-
crisitem.author.parentorgMedicinski fakultet-
crisitem.author.parentorgMedicinski fakultet-
crisitem.author.parentorgMedicinski fakultet-
Appears in Collections:MDF Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

2
checked on May 20, 2023

Page view(s)

31
Last Week
5
Last month
2
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.