Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/2641
DC FieldValueLanguage
dc.contributor.authorRistic-Djurovic J.en_US
dc.contributor.authorGajić, Slavicaen_US
dc.contributor.authorIlić, Anđelijaen_US
dc.contributor.authorRomcevic N.en_US
dc.contributor.authorDjordjevich D.en_US
dc.contributor.authorDe Luka S.en_US
dc.contributor.authorTrbovich A.en_US
dc.contributor.authorSpasić Jokić, Vesnaen_US
dc.contributor.authorCirkovic S.en_US
dc.date.accessioned2019-09-23T10:22:46Z-
dc.date.available2019-09-23T10:22:46Z-
dc.date.issued2018-06-01-
dc.identifier.issn02780046en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/2641-
dc.description.abstract© 1982-2012 IEEE. With the expanding usage of various devices, which emit static and extremely low-frequency magnetic fields, increases the number of biomedical reports on their influence as well as demand for suitable experimental exposure systems. Experimental setups range from permanent magnets through Helmholtz coils to solenoids; however, almost all of them provide relatively weak magnetic fields of up to 10 mT. Widespread use of devices such as MR scanners imposes intentional as well as unintentional exposure to stronger fields. A typical solenoid produces stronger although less homogeneous field than the most commonly used experimental equipment composed of sets of coaxial coils. In order to provide scalable, relatively strong, low-varying field within experimental volume that is large enough for in vivo as well as in vitro experiments modified solenoids are considered. Variation of the field was reduced by modifying the shape and size of solenoid's cross section. Modified solenoids were modeled analytically, numerically, and as a prototype. Solenoid geometries were optimized for maximal field performance and minimal power consumption. The optimal modified solenoids scalable to desired sizes of the experimental volume and values of maximal magnetic induction intensities are offered. The suggested solenoid modification method can decrease field variation as much as 10.6 times.en
dc.relation.ispartofIEEE Transactions on Industrial Electronicsen
dc.titleDesign and Optimization of Electromagnets for Biomedical Experiments with Static Magnetic and ELF Electromagnetic Fieldsen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.1109/TIE.2017.2772158-
dc.identifier.scopus2-s2.0-85034244584-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85034244584-
dc.description.versionUnknownen_US
dc.relation.lastpage5000en
dc.relation.firstpage4991en
dc.relation.issue6en
dc.relation.volume65en
item.grantfulltextnone-
item.fulltextNo Fulltext-
Appears in Collections:Naučne i umetničke publikacije
Show simple item record

SCOPUSTM   
Citations

17
checked on Mar 15, 2024

Page view(s)

23
Last Week
15
Last month
0
checked on May 3, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.