Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/18458
DC FieldValueLanguage
dc.contributor.authorPodraščanin Zorica-
dc.contributor.authorIrena Balog-
dc.contributor.authorJanković Aleksandar-
dc.contributor.authorMijatović Zoran-
dc.contributor.authorZoltan Nadj-
dc.date.accessioned2020-12-13T12:45:19Z-
dc.date.available2020-12-13T12:45:19Z-
dc.date.issued2017-
dc.identifier.issn0033-4553-
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/18458-
dc.description.abstract© 2017, Springer International Publishing AG. In this paper, we present consecutive daily measurements of the total ozone column (TOC) using MICROTOPS II in Novi Sad, the Republic of Serbia (45.3 N, 19.8 E and the altitude of 84 m) from 2007 to 2015. The MICROTOPS II data set was compared to the ozone monitoring instrument (OMI) satellite data, since there was no nearby comparative long-time series available for the Dobson or Brewer instrument. The data quality control of the measured MICROTOPS II TOC data was carried out before the comparison with the satellite data. The MICROTOPS II was calibrated at the manufacturer’s facilities and only TOC values drawn from the 305.5/312.5 nm wavelength combination were compared with the satellite data. The mean bias deviation between MICROTOPS II and OMI satellite data sets was obtained to be less than 2%, and the mean absolute deviation was in the range of 5%. The difference in the mean seasonal TOC values in summer and autumn was less than 0.5%, while in winter and spring this difference reached 2.8%. A possible calibration of MICROTOPS II instrument with the satellite data is presented, where the calibration coefficients for all channels were calculated for every satellite and MICROTPS II data pair during one year. Then, the average value of all the calculated coefficients was used for instrument calibration. The presented calibration improves the MICROTOPS II instrument stability and enables the usage of all the wavelength combinations.-
dc.language.isoen-
dc.relation.ispartofPure and Applied Geophysics-
dc.sourceCRIS UNS-
dc.source.urihttp://cris.uns.ac.rs-
dc.titleA Comparison of MICROTOPS II and OMI Satellite Ozone Measurements in Novi Sadfrom 2007 to 2015-
dc.typeJournal/Magazine Article-
dc.identifier.doi10.1007/s00024-017-1665-0-
dc.identifier.scopus2-s2.0-85036480084-
dc.identifier.urlhttps://www.cris.uns.ac.rs/record.jsf?recordId=106834&source=BEOPEN&language=en-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85036480084-
dc.relation.lastpage4499-
dc.relation.firstpage4489-
dc.relation.issue12-
dc.relation.volume174-
dc.identifier.externalcrisreference(BISIS)106834-
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.deptDepartman za fiziku-
crisitem.author.deptКatedra za društvene nauke-
crisitem.author.deptDepartman za fiziku-
crisitem.author.orcid0000-0003-2196-1831-
crisitem.author.orcid0000-0001-9966-5165-
crisitem.author.parentorgPrirodno-matematički fakultet-
crisitem.author.parentorgPedagoški fakultet-
crisitem.author.parentorgPrirodno-matematički fakultet-
Appears in Collections:PMF Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

1
checked on Aug 12, 2023

Page view(s)

26
Last Week
7
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.