Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/1725
DC FieldValueLanguage
dc.contributor.authorĐurović, Anaen_US
dc.contributor.authorStojanović, Zoricaen_US
dc.contributor.authorKravić, Snežanaen_US
dc.contributor.authorRakić, Dušanen_US
dc.contributor.authorGrahovac, Nadaen_US
dc.date.accessioned2019-09-23T10:17:25Z-
dc.date.available2019-09-23T10:17:25Z-
dc.date.issued2018-03-16-
dc.identifier.issn03067319en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/1725-
dc.description.abstract© 2018 Informa UK Limited, trading as Taylor & Francis Group. In this paper, a chronopotentiometric method for the determination of herbicide metamitron (MTM) using a glassy carbon electrode (GCE) and a thin film mercury electrode (TFME) as working electrodes is presented. MTM provided a well-defined reductive peak in the Britton–Robinson buffer on both working electrodes. Instrumental and chemical factors such as pH of the buffer, initial potential and reduction current influencing MTM chronopotentiometric response were optimised with the Box–Behnken experimental design. Under the optimal combination of factors, the analytical signal was linear in the MTM concentration range of 0.8–30 mg/L, with a detection limit of 68.53 µg/L using a TFME, and in the concentration range of 1–30 mg/L, with a detection limit of 92.91 µg/L using a GCE. The precision of the method was estimated as a function of repeatability and reproducibility, with the value of relative standard deviation lower than 2.6%. The applicability of the method was verified by direct analysis of MTM in spiked water samples and commercial pesticide formulations. The obtained results were in good agreement with those obtained using liquid chromatography/tandem mass spectrometry (LC-MS/MS) method, or with those labelled by the manufacturer. By using chronopotentiometry, neither extraction nor preconcentration procedures are necessary, thus making this method simple, cost-effective and more feasible for analytical routine analysis.en_US
dc.language.isoenen_US
dc.relation.ispartofInternational Journal of Environmental Analytical Chemistryen_US
dc.titleNovel electrochemical procedure for the determination of metamitronen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.1080/03067319.2018.1469625-
dc.identifier.scopus2-s2.0-85046801321-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85046801321-
dc.description.versionPublisheden_US
dc.relation.lastpage385en_US
dc.relation.firstpage369en_US
dc.relation.issue4en_US
dc.relation.volume98en_US
item.grantfulltextnone-
item.fulltextNo Fulltext-
crisitem.author.deptTehnološki fakultet, Katedra za primenjene i inženjerske hemije-
crisitem.author.deptTehnološki fakultet, Katedra za primenjene i inženjerske hemije-
crisitem.author.deptTehnološki fakultet, Katedra za primenjene i inženjerske hemije-
crisitem.author.deptTehnološki fakultet, Katedra za opšte inženjerske discipline-
crisitem.author.orcid0000-0002-3091-1898-
crisitem.author.orcid0000-0001-8892-3157-
crisitem.author.orcid0000-0003-4056-2000-
crisitem.author.orcid0000-0002-6942-4421-
crisitem.author.parentorgTehnološki fakultet-
crisitem.author.parentorgTehnološki fakultet-
crisitem.author.parentorgTehnološki fakultet-
crisitem.author.parentorgTehnološki fakultet-
Appears in Collections:TF Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

7
checked on May 3, 2024

Page view(s)

35
Last Week
13
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.