Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/165
DC FieldValueLanguage
dc.contributor.authorJanulyte, Aurikaen_US
dc.contributor.authorZerega, Yvesen_US
dc.contributor.authorBrkić, Borisen_US
dc.contributor.authorTaylor, Stephenen_US
dc.contributor.authorAndre, Jacquesen_US
dc.date.accessioned2019-09-23T10:04:36Z-
dc.date.available2019-09-23T10:04:36Z-
dc.date.issued2019-06-
dc.identifier.issn0267-9477en_US
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/165-
dc.description.abstractSpectral peak separations of 4 m/z were previously measured using a small-scale mass spectrometer. In this paper the use of He buffer gas during mass analysis was investigated in order to obtain better peak separations (1 m/z) and to optimize the design prior to construction of a new linear ion trap (LIT) device with a novel electrode arrangement and operating mode. Ion/neutral collisions were simulated during LIT operation with an event driven statistical collision treatment tool using 3D electric field boundary element modelling software. Using He buffer gas during the LIT cooling step and assuming a collision-free isolation step during the LIT operating mode, 1 m/z separation can be obtained with also an increased instrument sensitivity. This requires adaptation of both the LIT operating mode and the LIT device configuration. These performance improvements come at the expense of an increase in the analysis duration time which however remains acceptable.en_US
dc.publisherThe Royal Society of Chemistryen_US
dc.relation.ispartofJournal of Analytical Atomic Spectrometryen_US
dc.titleAccurate modelling of small-scale linear ion trap operating mode using He buffer gas to improve sensitivity and resolution for in-the-field mass spectrometryen_US
dc.typeJournal/Magazine Articleen_US
dc.identifier.doi10.1039/c9ja00017h-
dc.identifier.scopus2-s2.0-85070273427-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85070273427-
dc.description.versionPublisheden_US
dc.relation.lastpage1682en_US
dc.relation.firstpage1672en_US
dc.relation.issue8en_US
dc.relation.volume34en_US
item.grantfulltextnone-
item.fulltextNo Fulltext-
crisitem.author.deptInstitut BioSense-
crisitem.author.orcid0000-0003-2427-7154-
crisitem.author.parentorgUniverzitet u Novom Sadu-
Appears in Collections:IBS Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

2
checked on Apr 29, 2023

Page view(s)

38
Last Week
26
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.