Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/1267
DC FieldValueLanguage
dc.contributor.authorAnojčić J.en
dc.contributor.authorGuzvanj (Guzsvány), Valerija (Valéria)en
dc.contributor.authorVajdle O.en
dc.contributor.authorKónya Z.en
dc.contributor.authorKalcher K.en
dc.date.accessioned2019-09-23T10:14:35Z-
dc.date.available2019-09-23T10:14:35Z-
dc.date.issued2018-10-01en
dc.identifier.issn00269247en
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/1267-
dc.description.abstract© 2018, Springer-Verlag GmbH Austria, part of Springer Nature. Abstract: The present work describes the preparation of a simple, sensitive, and reliable H2O2 sensor made from carbon paste surface modified with a composite of platinum nanoparticles (< 5 nm) on graphitized carbon (Pt-C, 10% Pt on Vulcan XC72) by simply drop-coating. The unmodified carbon paste electrode (CPE) and the modified one (Pt-C/CPE) were characterized by scanning electron microscopy in combination with energy-dispersive X-ray spectrometry and by cyclic voltammetry. The Pt-C/CPE showed remarkable electrocatalytic properties toward the electrochemical redox reaction of H2O2 compared to CPE in phosphate (0.1 mol dm−3; pH 7.50) and acetate (0.1 mol dm−3; pH 4.50) buffer supporting electrolytes. Amperometry of H2O2 in the concentration range from 0.15 to 1.45 µg cm−3 with the Pt-C/CPE showed acceptable linearity, while the obtained values of LOQs were 0.06 µg cm−3 (pH 7.50, working potential 0.20 V, stirred solution) and 0.10 µg cm−3 (pH 4.50, working potential 0.50 V). The proposed analytical methods were applied to the determination of the H2O2 content in commercially available personal care products: disinfection (pH 7.50) and contact lens cleaning (pH 4.50) solutions. In both cases, obtained amperometric results are in good agreement with those measured by the traditional spectrophotometric method and with H2O2 concentration declared by producers. The Pt-C/CPE was also tested for monitoring of the H2O2 residual concentration in contact lens solution during its neutralization/decomposition process by solid Pt catalyst. At 6 h of neutralization treatment, 24.68 μg cm−3 of the H2O2 was determined which is below allowed H2O2 concentration concerning the limit of eye irritation. Graphical abstract: [Figure not available: see fulltext.].en
dc.relation.ispartofMonatshefte fur Chemieen
dc.titleRapid amperometric determination of H<inf>2</inf>O<inf>2</inf> by a Pt nanoparticle/Vulcan XC72 composite-coated carbon paste electrode in disinfection and contact lens solutionsen
dc.typeJournal/Magazine Articleen
dc.identifier.doi10.1007/s00706-018-2253-4en
dc.identifier.scopus2-s2.0-85052336723en
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85052336723en
dc.relation.lastpage1738en
dc.relation.firstpage1727en
dc.relation.issue10en
dc.relation.volume149en
item.grantfulltextnone-
item.fulltextNo Fulltext-
crisitem.author.deptPrirodno-matematički fakultet, Departman za hemiju, biohemiju i zaštitu životne sredine-
crisitem.author.parentorgPrirodno-matematički fakultet-
Appears in Collections:PMF Publikacije/Publications