Please use this identifier to cite or link to this item: https://open.uns.ac.rs/handle/123456789/10418
DC FieldValueLanguage
dc.contributor.authorIlić M.-
dc.contributor.authorAčanski, Marijana-
dc.contributor.authorPastor, Kristian-
dc.contributor.authorPopović L.-
dc.contributor.authorJovanović-Šanta, Suzana-
dc.date.accessioned2020-03-03T14:39:24Z-
dc.date.available2020-03-03T14:39:24Z-
dc.date.issued2020-
dc.identifier.issn10826076-
dc.identifier.urihttps://open.uns.ac.rs/handle/123456789/10418-
dc.description.abstract© 2019, © 2019 Taylor & Francis Group, LLC. The retention behavior, lipophilicity of 16,17-secoestrone derivatives and efficiency in the separation of halogenated derivatives by HPLC with pentafluorophenyl-propyl stationary phase (F5) were studied. Methanol-water (MeOH-W) and acetonitrile-water (ACN-W) were used as mobile phases in proportions according to nomograph of iso-eluotropic binary solvent mixtures. Since mobile phase ACN-W was more effective eluent, the retention behavior of 16,17-secoesterone derivatives has further been evaluated, with water content increasing in increments of 5%. The retention constants log k for mobile phases MeOH-W and ACN-W, have been compared by applying Student’s paired t-test and Fisher’s F-test to determine the applicability of the nomograph to this column. Linear correlations were obtained between parameters log k0 and log P, as well as φ0 and log P, for both MeOH-W and ACN-W eluents. Compared with log k0, the hydrophobicity index φ0 proved to be better parameter for lipophylicity estimation of these compounds. According to the separation efficacy of individual components, as well as mixtures of halogenated secoestone compounds, chromatographic columns can be placed in the following order: C18> F5> C8. This result is of huge importance for the field of synthesis, purification and characterization of novel biologically and pharmacologically active compounds and steroids among them.-
dc.language.isoen-
dc.relation.ispartofJournal of Liquid Chromatography and Related Technologies-
dc.sourceCRIS UNS-
dc.source.urihttp://cris.uns.ac.rs-
dc.titleNew challenge in the lipophilicity determination and separation of biologically active 16,17-secoesterone derivatives by HPLC–Use of pentafluorophenyl-propyl column-
dc.typeJournal/Magazine Article-
dc.identifier.doi10.1080/10826076.2019.1674662-
dc.identifier.scopus2-s2.0-85074601866-
dc.identifier.urlhttps://api.elsevier.com/content/abstract/scopus_id/85074601866-
dc.relation.lastpage117-
dc.relation.firstpage106-
dc.relation.issue3-4-
dc.relation.volume43-
dc.identifier.externalcrisreference(BISIS)116098-
item.fulltextNo Fulltext-
item.grantfulltextnone-
crisitem.author.deptTehnološki fakultet, Katedra za primenjene i inženjerske hemije-
crisitem.author.deptTehnološki fakultet, Katedra za primenjene i inženjerske hemije-
crisitem.author.deptPrirodno-matematički fakultet, Departman za hemiju, biohemiju i zaštitu životne sredine-
crisitem.author.orcid0000-0003-2673-403X-
crisitem.author.orcid0000-0003-0890-8171-
crisitem.author.orcid0000-0002-4579-5762-
crisitem.author.parentorgTehnološki fakultet-
crisitem.author.parentorgTehnološki fakultet-
crisitem.author.parentorgPrirodno-matematički fakultet-
Appears in Collections:PMF Publikacije/Publications
TF Publikacije/Publications
Show simple item record

SCOPUSTM   
Citations

3
checked on May 10, 2024

Page view(s)

33
Last Week
8
Last month
0
checked on May 10, 2024

Google ScholarTM

Check

Altmetric


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.